background image

Bantam Plus Getting Started Guide v6 

 

27 

Radian Research, Inc. 

  

 

 
 

 

 

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Figure 6

 Touch Screen Keyboard 

Figure 7

 Numeric Screen Keyboard 

Figure 8

 Windows Screen Keyboard 

Содержание Bantam Plus

Страница 1: ......

Страница 2: ...out our written consent or in circumstances that may cause us commercial harm The operation of this equipment requires training and experience in electric meter testing The information in this getting...

Страница 3: ...am Plus 14 1 5 2 RB 2X I O Connection 15 2 Operation Preparation 17 2 1 Getting Started 17 2 1 1 Thank you for your purchase 17 2 1 2 Preparing Equipment for Use 18 2 1 3 Registering Your Equipment 21...

Страница 4: ...6 1 Utilities Overview 37 7 RB 2X Site Information Application 39 7 1 Site Information Application Overview 39 8 Routine Maintenance and Service 41 8 1 Contact Information 41 8 2 Routine Maintenance 4...

Страница 5: ...22 Figure 5 Bantam Plus Main Menu Screen 26 Figure 6 Touch Screen Keyboard 27 Figure 7 Numeric Screen Keyboard 27 Figure 8 Windows Screen Keyboard 27 Figure 9 Bantam Plus Screen Tour 30 Figure10 Bant...

Страница 6: ...tandards Compare Edit Meter Test Forms and Assign Operator Profiles Read results Transfer Meter Measurement data to an external controller 1 Product Introduction and Specifications This chapter provid...

Страница 7: ...Figure 1 Figure 1 RB 2X Bantam Plus Portable Test System Automated Meter Test Socket Sensor Pro Infrared and Visible Light optical sensor Interface panel to access external sensors computer peripheral...

Страница 8: ...tage RB MTA Meter Test Adapter An assembly that plugs into the Bantam Plus meter socket and delivers voltage and current 20 Amps max to the meter test socket see section 4 2 2 RB FPC RB 2x Field Power...

Страница 9: ...ility RB MECH 90 Degree Adapter for mechanical meters RM 1S The RM 1S Remote Reset Switch is a normally closed push button switch The push button has a tactile feel to provide instantaneous feedback o...

Страница 10: ...o RD 2x Standards Compare Adapter Used to interface with an external RD for calibration purposes RB SMK RB 2x Socket Maintenance Kit Contains pack of six field replacement socket assemblies and one To...

Страница 11: ...rms 1S 2S 3S 4S 5S 6S 8S 9S 10S 12S 13S 14S 15S 16S 25S 26S 29S 35S 36S 45S 46S 56S 66S 96S Optional CT Burden testing Lightweight 1 3 2 RB 2X Embedded Winboard Software The RB 2X Winboard Automated s...

Страница 12: ...without first gaining the basic knowledge of meter testing and the application of meter testing equipment from a certified training course Operation of this equipment involves high voltage Always wear...

Страница 13: ...or Operations Manual 1 4 3 Conventions Used in this Getting Started Guide The following conventions are used in this getting started guide to highlight important information Indicates an imminently ha...

Страница 14: ...1 5 lbs 14 29 kg Warranty 2 year warranty against defects in material or workmanship care plans are available to extend warranty Electrical Protection Line power 5 A Breaker Reference standard Contain...

Страница 15: ...state meters but also allows the operator to program the meter without changing the optical head Optocom is a registered trade mark of Optocom Corporation Port 2 A LEMO connector reserved for optical...

Страница 16: ...n two outputs can be software set high or low There is also an unregulated 12VDC output The following illustration depicts the connection diagram of the advanced I O connector IOIOIO A serial port use...

Страница 17: ...recognized throughout the world for their unparalleled accuracy precision and stability We have taken every effort to ensure that your RB 2X Bantam Plus Portable Test System reaches you in perfect co...

Страница 18: ...amage to the equipment immediately notify the carrier and your sales representative 2 Verify the contents The following items are included in your shipment o RB 2X Bantam Plus o RB SPC 10 Shop Power c...

Страница 19: ...efine fields If you wish to customize the fields or are already using WATT Net within your organization you may purchase optional customization packages For more information on customization contact y...

Страница 20: ...nt to Activate the equipment warranty Receive firmware and software updates as well as product application notes from Radian Research Inc You must register your equipment at www radianresearch com reg...

Страница 21: ...radianresearch com reg 2 Complete the online form The model number is either RB 20 or RB 21 and is found on nameplate The serial number can be found on the nameplate as shown in Figure 3 Figure 3 RB 2...

Страница 22: ...s Portable Test System for use do not block the cooling vents on the front and back as shown in Figure The RB 2X cooling fan is temperature controlled and will only operate when the internal temperatu...

Страница 23: ...ower and protect the Bantam Plus The input voltage operating range is 90V to 300V The design will source 69V to 480V to the meter socket Breaker switch is rated at 5 Amps The Bantam Plus software oper...

Страница 24: ...so allows the operator to program the meter without changing the optical head external PC required This connector may also be used for custom pickups as required Contact Radian for any special needs t...

Страница 25: ...ddition two outputs can be software set high or low There is also an unregulated 12VDC output 8 Serial Interface The RS232 serial interface connector is a multi function input connector that can be us...

Страница 26: ...programs activate buttons or otherwise interact with the unit To perform a right click using a stylus Click stylus to the touch screen and hold it in place for a few seconds NOTE Inter nal fans may no...

Страница 27: ...Bantam Plus Getting Started Guide v6 27 Radian Research Inc Figure 6 Touch Screen Keyboard Figure 7 Numeric Screen Keyboard Figure 8 Windows Screen Keyboard...

Страница 28: ...the banana sockets on the rear panel of the Bantam Plus Live and Neutral orientation is not important as supplies are fully isolated and fused on both neutral and live 4 Insert the plug end of the Sho...

Страница 29: ...d lug 6 Clamp one lead from the Field Power Cord onto the neutral lower side test switch Clamp the other lead from the Field Power Cord onto the phase A lower side test switch 7 When the last connecti...

Страница 30: ...You will hear an audible tone three times from internal RD Reference Standard during power up this indicate the internal reference standard is operational 2 See Figure 9 for a Bantam Plus screen tour...

Страница 31: ...ead 1 inch between the Meter glass and the sensor Use the target on the Sensor Pro to assist in alignment 6 The integrated Sensor Pro is assigned to Optics 2 Port 2 Select Adjust Optics button from th...

Страница 32: ...ting 8 Validate the Meter form and Kh value is correct Review the test sequence for appropriate steps before selecting the Start soft key 9 Select start and validate the Voltage and Current LEDs on th...

Страница 33: ...earch Inc If a run is repeated the data from a second test will populate the AS LEFT field 10 To cancel a meter test at any time select CANCEL from the display softkey 11 Results may be viewed from th...

Страница 34: ...4 Connect the RB MTA alligator clips to the meter test switch Care should be taken to ensure the elements are correctly matched for the meter under test and the meter test switch used For more details...

Страница 35: ...ow shows the Administration application screen An overview of each function is summarized Figure 12 RB 2X Administration View 5 1 1 Edit Form Defaults Bantam Plus is supplied with all ANSI forms alrea...

Страница 36: ...wn Code is used to customize the valid values associated with a field defined in the Edit DataView and Import Export Setting screen An example of codes defined in the Edit Drop Down Codes screen would...

Страница 37: ...chapter describes the Utilities Application structure of the RB 2X and contains the following section 6 1 Utilities Overview 6 1 Utilities Overview Figure 13 below shows the Administration Applicatio...

Страница 38: ...low THD To simulate real world phenomena the source is capable of generating harmonics from the voltage current source 6 1 3 External RD Comm enables an external PC to communicate directly with the i...

Страница 39: ...ing workflow Site information is a collection of data specific to a location where a meter or meters current transformer potential transformer or combination of these is regularly tested You enter the...

Страница 40: ...Load Site Information allows the operator review edit previously saved site information 7 1 3 Site Report allows the operator to select review and print a site report Figure 15 View of the Meter Test...

Страница 41: ...an Research Inc 3852 Fortune Drive Lafayette IN 47905 USA Tel 765 449 5500 Fax 765 448 4614 Email radian radianresearch com Website www radianresearch com 8 2 Routine Maintenance The RB 2X Bantam Plus...

Страница 42: ...ary to operate to specification The following procedure describes how to periodically clean or replace these jaws Step 1 Ensure the Bantam Plus is switched off and isolated from line voltage Step 2 Re...

Страница 43: ...crews Step 7 Perform a Standards Compare to validate the performance using Standards Compare information found in section 6 1 Figure 16 Removable Socket Liners The RB 2X Bantam Plus Portable Test Syst...

Страница 44: ...sts to return the product to the customer Radian will not pay for overnight or express shipping service Use the following address for warranty returns Radian Research Inc 3852 Fortune Drive Lafayette...

Страница 45: ...ed description of the problem and the events that led up to the development of the problem Radian Research Inc will invoice return shipping costs to the customer 8 4 Helpful Documentation and Resource...

Отзывы: