10
Owner’s Manual:
05025X1
1786850 Rev L
ECO 17-0032
Feb 2020
www.radiaproducts.com (PHONE) 800-221-1083 | (INTL) +1-763-533-2969 | (FAX) 763-533-0015
PROBLEM
CAUSE
REMEDY
6. Troubleshooting
6. Troubleshooting
Not connected to power source
Motor thermal protector
activated
Building ciruit breaker or fuse
blown
Machine door does not make
contact with limit switch
Machine circuit breaker tripped
Pail damaged
Faulty controller
Faulty door limit switch
Bearings worn or
damaged
Top clamp pad worn
Top clamp not secure
Connect to power source
Reset breaker or replace fuse
Read just switch to make contact with
limit switch screw when door is closed
Reset by pressing circuiut breaker
back in
Fix or replace pail
Contact Radia Customer Care
Contact Radia Customer Care
Contact Radia Customer Care
Allow to cool, then restart
Replace pad
Turn the crank handle down until top plate is
snug on pail
Machine won't operate
Pail won't fit properly into
clamping plates
Machine doesn't shut off
at end of mixing cycle
Machine doesn't shut off
when door is opened
Increasing mechanical noise
Pail rotates inside the
clamping plates