1.
Load and position two one-gallon
containers as per section 4.3, Install
Containers.
2.
Release the E-STOP and switch the
power to ON.
3.
Press the green timer button. The clamp
will automatically travel down, clamp on
the cans, and begin mixing. The cycles
should be smooth. If there is noticeable
vibration, press the emergency stop switch
1.
Load a five-gallon pail as per section 4.2, Install
a Single Pail.
2.
Press the green timer button and let the
machine run for a full cycle. Again, watch the
machine closely for vibration that may indicate an
uneven condition.
3.
Remove the pail when the cycle ends and the
clamp has retracted.
1.
Load a container per Section 4.2, Install
Containers.
2.
Press the green, yellow, or blue button
to initiate a mixing cycle.
3.
After several seconds of mixing, press the
E-STOP switch. The machine will stop running.
Pull the E-STOP back out. The red mixing light
will begin to flash, indicating an interruption
in the mix cycle. After a pause, the top plate
will unclamp. This function will only work if the
emergency stop is activated, or if the power
switch is turned off during a mix cycle.
4.
Remove container.
5. Operations and Tests
5.1 One Gallon Test
5.3 Five Gallon Tests
5.2 E-STOP Test
5.4 Manual Door Lock Override
1.
Gently insert a small flat head screw driver
into latch hole.
2.
Lift screw handle to pivot tip down and
disengage lock.