9
1784242 Rev F
ECO 18-0034
July 2018
www.radiaproducts.com (PHONE) 800-221-1083 | (INTL) +1-763-533-2969 | (FAX) 763-533-0015
Owner’s Manual:
5315-X1
Disconnect the machine from its power source before servicing
.
6. Troubleshooting
PROBLEM
CAUSE
REMEDY
Not connected to power source
Connect to power source
Building circuit breaker or fuse
blown
Reset breaker or replace fuse
Machine door does not make
contact with limit switch
Re-adjust switch to make contact
wit limit switch screw when door is
closed
Motor themral protector
activated
Contact Radia's Customer Care
Contact Radia's Customer Care
Faulty motor
Excessive Vibration
Can not properly seated
Adjust and level feet
Contact Radia's Customer Care
Machine dosen't shut off
when door is opened
Faulty door limit switch
Contact Radia's Customer Care
Increasing mechincal
noise
Bearings worn or damaged
Feet are not Level
Fix or replace pail
Reset can into holder
Allow to cool, then restart
Worn, damaged, or loose drive
belt
Unplug power cord, open mixer door,
and visually inspect the drive belt
Pail Damaged
Faulty door limit switch
Machine won't operate