A P P E N D I C E S
Series 8000™ O&M Manual
91
5.3.54
"Orbital tracking limit"
The ACU is attempting to track the target along a path bound by the
orbital tracking limit option.
The ACU may partially or completely lose the
target’s
signal during
this fault condition.
Troubleshooting:
1.
Increase the orbital tracking limit.
2.
Verify the tracking beamwidth.
3.
Increase the Setup > Positioner > Deadband value (see sec-
tion 3.5.6
).
4.
Disable orbital track by setting the Setup > Options > Orbital
tracking limit to 0.
5.3.55
"Sun outage"
The ACU has detected that a sun outage event will occur or is current-
ly occurring. It will prevent further steptrack cycles until the sun out-
age event has passed.
5.3.56
"PMCU firmware update failed"
Troubleshooting:
1.
Clear the fault and verify system is operating normally.
2.
If not, cycle power at the drive cabinet.
3.
If issues persist, contact support.