3.1 Intended use / operational conditions
Only use the tubular motors for the electrical
operation (raising and lowering) of screens in Zip
systems.
The use of the wrong tubular motors or compo-
nents can lead to property damage.
◆
When used outdoors, the motor cable must be
fitted with a suitable empty tube up to the re-
spective junction box taking account of the local
electrical regulations.
◆
Only use the manufacturer's original parts and
accessories.
◆
Only use tubular motors which correspond to
the local conditions in terms of their power.
Incorrectly dimensioned tubular motors can lead
to damage:
> An under-dimensioned tubular motor can be
damaged by overloading or may result in the
screen not raising.
> An over-dimensioned tubular motor may not
switch off with the necessary sensitivity in the
case of a blockage and damage the screen or
mechanism.
◆
Consult a specialist retailer when selecting a
tubular motor and observe the corresponding
tractive force specifications on our website:
www.rademacher.de
Operating conditions
◆
A 230 V / 50 Hz power supply, together with a
site-provided isolating device (fuse), must be per-
manently available for the electrical connection at
the installation location.
◆
The mechanism must run up and down easily and
should not jam.
◆
Installation and operation of the RolloTube S-line Zip
DuoFern is only permitted for those systems and
devices where a malfunction in the transmitter or
receiver would not cause a danger to personnel
or property or where this risk is already covered
by other safety equipment.
i
Radio systems that transmit on the same
frequency can cause
interference.
Operating conditions for self-learning mode
◆
The screen requires a fixed end stop when raised
in order to be able to learn the end point.
3.2 Improper use
Using the RolloTube S-line Zip DuoFern for purposes
other than previously mentioned is impermissible.
Never use the tubular motor in continuous opera-
tion. Doing so will cause serious damage.
i
3.3 Expert knowledge required of the installer
The installation, electrical connection and main-
tenance must be carried out by a qualified person
with appropriate training or by a specialist com-
pany in accordance with the instructions in this
manual.
i
i
Never use the DuoFern radio system and its
components for the remote control of applianc-
es and systems with increased safety-relevant
requirements or where there is an accident risk.
◆
Applications of this kind require additional safe-
ty equipment. Observe the respective statutory
regulations for the installation of such systems.