17
1145094-W2-D
Flow regulator
(for high pressure
systems)
Grubscrew
5.
Fit the supply pipework (
Hot - Left,
Cold - Right
).
6.
Loosen the grubscrew with the
2.5 mm hexagon key (supplied) and
remove the backplate from the mixer.
7.
Secure the backplate to the wall using
the screws (supplied).
Caution!
It is essential at this point
that the supply pipework is thoroughly
flushed through before connection to
the mixer. Failure to do so may result
in product malfunction.
8.
Fit the compression nuts and olives
onto the pipework.
9.
Align the mixer with the pipework and
fit onto the backplate.
10.
Tighten the compression nuts onto
the mixer with a suitable spanner.
Caution!
Take care not to damage
the chrome surfaces.
11.
Tighten the grubscrew to secure the
mixer to the backplate.
12.
Fit the
Shower Fittings
, refer to your
Shower Fittings Product Manual for
Instructions.
Note!
For high pressure systems,
a 6 or 9 litre/minute flow regulator
(supplied) can be fitted under the
hose washer (refer to illustration).
13.
Turn on the hot and cold water
supplies and check for leaks.
14.
Before using the shower, refer to
section:
‘Commissioning’
.
Hot
Cold
Содержание V12