background image

36

1145094-W2-D

© Kohler Mira Limited, October 2011

Guarantee

Your  product  has  the  benefit  of  our  manufacturer’s 

guarantee which starts from the date of purchase.

Within  the  guarantee  period  we  will  resolve  defects  in 

materials or workmanship, free of charge, by repairing or 

replacing parts or product as we may choose.

This guarantee is in addition to your statutory rights 

and is subject to the following conditions:

  ●  The  product  must  be  installed  and  maintained  in 

accordance with the instructions given in this guide.

  ●  Servicing  must  only  be  undertaken  by  us  or  our 

appointed  representative. 

Note!

  if  a  service  visit 

is  required  the  product  must  be  fully  installed  and 

connected to services.

  ●  Repair under this guarantee does not extend the original 

expiry date. The guarantee on any replacement parts 

or product ends at the original expiry date.

  ●  For shower fi ttings or consumable items we reserve 

the right to supply replacement parts only.

This guarantee does not cover:

  ●  Call  out  charges  for  non  product  faults  (such  as 

damage or performance issues arising from incorrect 

installation, improper use, inappropriate cleaning, lack 

of maintenance, build up of limescale, frost damage, 

corrosion, system debris or blocked fi lters) or where no 

fault has been found with the product.

  ●  Water or electrical supply, waste and isolation issues.

  ●  Compensation  for  loss  of  use  of  the  product  or 

consequential loss of any kind.

  ●  Damage or defects caused if the product is repaired 

or  modifi ed  by  persons  not  authorised  by  us  or  our 

appointed representative.

  ●  Routine maintenance or replacement parts to comply 

with the requirements of the TMV2 or TMV3 healthcare 

schemes.

  ●  Accidental or wilful damage.

  ●  Products purchased ex-showroom display.

What to do if something goes wrong

If your product does not function correctly when you fi rst 

use  it,  contact  your  installer  to  check  that  it  is  installed 

and commissioned in accordance with the instructions in 

this guide.

If this does not resolve the issue, contact our Customer 

Services Team  who  will  offer  you  or  your  installer  help 

and advice.

If the performance of your product declines, check in this 

guide to see if simple home maintenance is required. If you 

require further assistance call our Customer Services Team.

Technical Helpdesk Service

Our Customer Services Team is comprehensively trained 

and can offer help and advice, spare parts, accessories or 

a service visit.

We  will  need  you  to  have  your  model  name  or  number, 

power rating (if applicable) and date of purchase.

As part of our quality and training programme calls may be 

recorded or monitored.

Rada Website 

(www.radacontrols.com)

From our website you can view our full product catalogue 

or download a brochure.

Spares and Accessories

We  maintain  extensive  stocks  of  genuine  spares  and 

accessories  and  aim  to  provide  support  throughout  the 

product’s expected life.

Payment can be made by phone at time of order using most 

major Credit or Debit cards and we aim to despatch orders 

within two working days.

Items purchased from us are guaranteed for 12 months 

from date of purchase.

For  safety  reasons  spares  exposed  to  mains  voltages 

should only be fi tted by competent persons.

Returns

 – items can be returned within one month of date 

of purchase, providing that they are in good condition and 

the packaging is unopened. If you wish to return any items 

please notify us in writing with seven days of receipt.

Service / Repairs

Our nationwide team of Service Technicians can carry out all 

service or repair work to your product within the guarantee 

period and beyond.

You  have  the  assurance  of  a  fully  trained  Technician, 

genuine Rada spare parts and a 12 month guarantee on 

any chargeable work done.

Service Contracts

A regular service visit ensures your product continues to 

perform at the peak of performance. We offer annual or

biannual servicing carried out by our fully trained technicians 

subject to site survey.

To Contact Us - Customer Service and 

Specifi cation Enquiries UK

Telephone: 0844 571 1777

E-mail: [email protected]

Fax: 0844 472 3076

By Post: Rada Controls, Cromwell Road, Cheltenham, 

Gloucestershire, GL52 5EP

Rada is a registered trade mark of 

Kohler Mira Limited.

The company reserves the right to alter 

product specifi cations without notice.

FM 14648

CUSTOMER SERVICE

Содержание V12

Страница 1: ...1145094 W2 D IMPORTANT Installer This Manual is the property of the customer and must be retained with the product for maintenance and operational purposes PRODUCT MANUAL V12 THERMOSTATIC SHOWER VALV...

Страница 2: ...2 1145094 W2 D...

Страница 3: ...nections 10 Installation 12 General 12 Installation Methods 13 Rada V12 Exposed Shower Valve 14 Rear Entry Supplies rising or falling concealed pipework 14 Rising or Falling Supplies 16 Rada V12 Conce...

Страница 4: ...l min flow regulator is supplied for high pressure systems to reduce excessive shower force For additional water saving a 6 l min flow regulator is also included The Thermostatic Mixer incorporates a...

Страница 5: ...arnings cautions and instructions contained in this guide 4 Anyone who may have difficulty understanding or operating the controls of any shower should be attended whilst showering Particular consider...

Страница 6: ...V12 Exposed Shower Valve 1 x O Key 2 x Olives 2 x InsuTech Compression Nuts 2 x Concealing Plates 1 x 2 5 mm Hexagon Key 2 x No 8 x 1 Securing Screws 2 x Wall Plugs Rada V12 Exposed Shower Valve 1 x...

Страница 7: ...led Shower Valve attached to the Building in Shroud 1 x Concealing Plate 2 x M5 x 40 mm Screws 2 x Securing Brackets 1 x O Key 4 x Bracket Securing Screws 1 x 6 L Min Flow Regulator Black 1 x 9 L Min...

Страница 8: ...t Manual 1 x TMV3 Requirements Manual 1 x O Key 2 x Olives 2 x Compression Nuts 2 x Concealing Plates 1 x 2 5 mm Hexagon Key 2 x No 8 x 1 Securing Screws 2 x Wall Plugs 1 x 6 L Min Flow Regulator Blac...

Страница 9: ...alve Rada V12 Concealed Shower Valve 111 mm 30 mm 108 mm 183 mm 60 84 mm 47 71 mm 20 mm 62 mm 58 mm Building in Depth 205 mm 153 mm Centres 109 mm 56 mm 62 mm 60 mm 122 mm 35 mm 130 mm 62 mm 56 mm 109...

Страница 10: ...65 C Note The Mixing Valve can operate at temperatures up to 85 C for short periods without damage However for safety reasons it is recommended that the maximum hot water temperature is limited to 65...

Страница 11: ...Rada V12 Shower Valve only Note Pressure Loss Inlet pressure outlet pressure measured at valve outlet 0 5 10 15 20 25 30 35 40 45 50 0 0 0 5 1 0 1 5 2 0 2 5 3 0 Outlet Flow l min Pressure Loss bar V12...

Страница 12: ...igidly supported and avoid any strain on the connections 5 Pipework dead legs should be kept to a minimum 6 Supply pipework layout should be arranged to minimise the effect of other outlet usage upon...

Страница 13: ...using Rear Fixing Points on the Body or by using the Securing Brackets supplied on the Front Face of a Solid Wall or Stud Partition or on the Rear Face of a Laminated Panel The hot water supply must a...

Страница 14: ...mm Apply Silicone Sealant Backplate Concealing Plates 10 mm minimum between Elbow and finished wall surface 32 mm 18 mm from finished wall surface Elbow 2 For solid walls drill the holes for the back...

Страница 15: ...the mixer with the pipework and fit onto the backplate 11 Tighten the compression nuts onto the mixer with a suitable spanner Caution Take care not to damage the chrome surfaces Note Make sure the com...

Страница 16: ...s Use as a support for the spirit level Hot Supply Inlet 15 mm Make sure that supply pipes are thoroughly flushed through before connection to the shower control Cold Supply Inlet 15 mm 153 mm 150 mm...

Страница 17: ...t the compression nuts and olives onto the pipework 9 Align the mixer with the pipework and fit onto the backplate 10 Tighten the compression nuts onto the mixer with a suitable spanner Caution Take c...

Страница 18: ...nd remove the two shroud screws and remove the building in shroud and chrome trim Retain the screws 3 Determine the position of the mixer and draw around the building in shroud 4 Mark the routes for t...

Страница 19: ...l two 6 mm holes for the wall plugs Caution Do not drill into pipes in the wall 10 Fit the wall plugs supplied and fix the mixer to the wall with the screws provided Note For stud partition installati...

Страница 20: ...ution Make sure that the finished wall is within the maximum and minimum limits and to an even depth no greater than 2 mm variation or the control components will not fit correctly 16 Remove the two s...

Страница 21: ...ll Thickness Depth X Rear Mounting 1 Refer to section Solid Wall or Stud Partition Using Securing Brackets Mounting off Front Face of Wall and follow steps 1 to 4 2 Cut away the plasterboard and or br...

Страница 22: ...the wall cavity or to a timber noggin 6 Refer to section Solid Wall or Stud Partition Using Securing Brackets Mounting off Front Face of Wall and follow steps 11 to 18 Laminated Panel Using Securing B...

Страница 23: ...position of the M5 fixing holes Important Make sure that the correct holes are used refer to illustration 6 Drill the two 5 5 mm holes for the fixing positions countersink the holes at the front 7 Sec...

Страница 24: ...ngs Product Manual for Instructions Note For high pressure systems a 6 or 9 litre minute flow regulator supplied can be fitted in the RAC Right Angled Connector See shower fittings kits 13 Fit the con...

Страница 25: ...h the backplate to the wall with the screws provided 6 Fit the concealing plate with the cut out at the bottom over the backplate until it clicks into position 7 Locate the bearing in the chrome trim...

Страница 26: ...he grubscrew then remove the control lever 3 Carefully unclip the concealing plate from the backplate Note Use a screwdriver in the cutout to assist separation Unscrew the two shroud screws and remove...

Страница 27: ...fer to the TMV3 Requirements Manual 1 Turn on the mixer to the maximum temperature i e fully anticlockwise and allow the temperature to stabilise If the temperature is too hot or too cold adjust as fo...

Страница 28: ...Rada V12 Exposed Shower Valve is supplied with inlet connections Hot Left Cold Right as standard If the hot and cold water supply pipes have been reversed during installation the mixer must be removed...

Страница 29: ...ectly e Airlock or partial blockage in pipework 3 No flow from the Mixer outlet a Check the Showerhead Hose and Filters for any blockage b Hot or cold supply failure 4 Blend temperature drift a Refer...

Страница 30: ...e Planned Maintenance Important For Type 3 Valves use the In Service Tests given in the TMV3 Requirements Manual In the absence of any other instruction or guidance on the means of determining the app...

Страница 31: ...the Warranty on the product will be void Exposed Models 1 Isolate the hot and cold water supplies and operate the control lever to drain any residual water 2 Carefully unscrew the filter caps and rem...

Страница 32: ...valves and operate the control lever to drain any residual water 4 Unscrew the Filter Caps with the O Key supplied or a 12 mm hexagonal wrench and remove the Filters Note Use pliers to carefully remov...

Страница 33: ...21 B Rada V12 Exposed Shower Valve 1651 142 Insutech Cold Inlet Assy 1651 144 Inlet Connector Pack 1651 145 Screw Pack identified B 1651 146 Outlet Plug 1651 147 Seal Pack identified A 1651 148 Elbow...

Страница 34: ...O Key 1595 149 Outlet Connector Pack 1651 133 Control Lever Assy 1651 134 Hub 1651 135 Body Trim 1651 136 Filter Pack x 2 1651 137 Flow Regulator 6 and 9 l min Rada V12 Concealed Shower Valve 1651 13...

Страница 35: ...1651 133 Control Lever Pack Assy 1651 137 Flow Regulators 6 and 9 l min 1651 140 Hub 1651 143 Filter Pack x 2 1651 146 Outlet Plug 1651 147 Seal Pack identified A 1651 148 Elbow Cap 1595 231 1651 149...

Страница 36: ...installer help and advice If the performance of your product declines check in this guide to see if simple home maintenance is required If you require further assistance call our Customer Services Tea...

Отзывы: