rada V10 Скачать руководство пользователя страница 24

24

1143923-W2-E 

Rada is a registered trade mark of 

Kohler Mira Limited.

The company reserves the right to alter 

14648

0844 571 1777

Fax: 0844 472 3076

Email – Visit 

[email protected]

 

By  Post:

 

Rada  Controls,  Cromwell  Road, 

Cheltenham, Gloucestershire GL52 5EP

To Contact Us: Eire Only

01 531 9337

E-mail: 

[email protected]

Calls cost 7p per minute plus your phone company’s 
access charge

Guarantee 

guarantee which starts from date of purchase.

 

Within 

the  guarantee  period  we  will  resolve  defects  in 

materials or workmanship, free of charge, by repairing 

or replacing parts or product as we may choose.

This  guarantee  is  in  addition  to  your  statutory 

rights and is subject to the following conditions:

  ●  The product must be installed and maintained 

   in accordance with the instructions given in this 

   user guide.

  ●  Servicing must only be undertaken by us or our 

   appointed representative. 

Note!

 If a service visit 

   is required the product must be fully installed and 

   connected to services.

  ●  Repair under this guarantee does not extend 

   the original expiry date. The guarantee on any 

   replacement parts or product ends at the original 

   expiry date.

  ● 

   reserve the right to supply replacement parts only.

The guarantee does not cover:

  ●  Call out charges for non product faults (such as 

   damage or performance issues arising from 

   incorrect installation, improper use, inappropriate 

   cleaning, lack of maintenance, build up of 

   limescale, frost damage, chemical attack, 

   

   where no fault has been found with the product.

  ●  Water or electrical supply, waste and isolation 

   issues.

  ●  Compensation for loss of use of the product or 

   consequential or indirect loss of any kind.

  ●  Damage or defects caused if the product is 

   

   us or our appointed representative. 

  ●  Routine maintenance or replacement parts to 

   comply with the requirements of the TMV2 or 

   TMV3 healthcare schemes

  ●  Accidental or wilful damage. 
  ●  Products purchased ex-showroom display.

What to do if something goes wrong

If your product does not work correctly refer to this 

manual  for  fault  diagnosis  and  check  that  it  is  in-

stalled  and  commissioned  in  accordance  with  our 

instructions.If this does not resolve the issue, contact 
us for help and advice.

Technical Helpdesk Service

Contact  our  Customer  Services  Team  for 

product  advice,  to  purchase  spare  parts  or 

accessories or to set up service visit. You can contact 

us via phone or e-mail - contact details below.

Please  provide  your  model  name,  power  rating  (if 

applicable) and date of purchase.

Rada Website (www.radacontrols.com)

From our website you can view our full product 

catalogue or download a brouchure.

Spares and Accessories

We hold the largest stocks of genuine Rada 

spares and accessories.

Service/Repairs

No one knows our products better than our 

nationwide team of Service Technicians. We 

can carry out service or repair work to your product  

both during and after the guarantee period.

You have the assurance of a fully trained Technician, 

genuine Rada spare parts and a 12 month guarantee 

on any chargeable work done.

Service Contracts

Regular servicing ensures your product continues to 

operate at the peak of performance. We offer annual 

or bi-annual servicing carried out by our fully trained 

technicians subject to site survey

To Contact Us - UK Customer Service & 

Your product has the benefit of our manufacture's

For shower fittings or consumable items we

corrosion, system debris or blocked filters) or

repaired or modified by persons not authorised by

Specification Enquiries

product specifications without notice.

© Kohler Mira Limited, May 2016

(B94Cb - B94Ab)

CUSTOMER SERVICE

Содержание V10

Страница 1: ...1143923 W2 E PRODUCT MANUAL V10 THERMOSTATIC SHOWER VALVE IMPORTANT Installer This Manual is the property of the customer and must be retained with the product for maintenance and operational purpose...

Страница 2: ...y water fittings Regulations 1999 The approved designations for Type 2 Valves are as follows Key High Pressure HP Low Pressure LP Models Designation Rada V10 LP S HP S HP SE The economy designation is...

Страница 3: ...instructions 2 Retain this guide for later use 3 Pass on this guide in the event of change of ownership of the installation site 4 Follow all warnings cautions and instructions contained in this guid...

Страница 4: ...alve q 1 x Rada V10 Exposed Shower Valve q 2 x Concealing Plates q 2 x Compression Nuts q 2 x Olives q 2 x Wall Plugs q 2 x Fixing Screws q 1 x 2 5 mm Hexagonal Key q 1 x Flow Regulator 6 l min q 1 x...

Страница 5: ...m Hexagonal Key q 1 x Concealing Plate Assembly Rada V10 Concealed Shower Valve q 1 x Rada V10 Concealed Shower Valve q 1 x Flow Regulator 6 l min q 1 x Flow Regulator 9 l min refer to section Flow Re...

Страница 6: ...q 2 x Fixing Screws q 1 x VR145 Showerhead q 1 x 3 mm Hexagonal Key q 1 x 2 5 mm Hexagonal Key q 1 x O Key q 2 x Wall Plugs q 2 x Fixing Screws q 1 x O Seal q 1 x Hole Plug q 1 x Flow Regulator 6 l m...

Страница 7: ...V10 Concealed Shower Valve Rada V10 Exposed Shower Valve Rada V10 Contract Pack 121 115 69 18 5 24 5 750 40 15 5 15 103 183 56 76 39 59 21 20 Building In Depth 50 36 5 115 126 54 19 30 50 46 76 5 41...

Страница 8: ...utlet Flow l min Outlet Flow l min 9l m Outlet Flow l min No Flow Regulators Pressure Loss bar Outlet Flow l min 9l m Outlet Flow l m Outlet Flow l min 6l m Outlet Flow l min No Flow Regulators Temper...

Страница 9: ...Mains Pressurised Instantaneous Hot Water System Combination Boiler The thermostatic mixer can be installed with systems of this type with balanced pressures Recommended Minimum Maintained Pressure 1...

Страница 10: ...V10 Exposed n a 6 L Min Black Supplied in the component pack designed to be fitted in the shower valve outlet Rada V10 Concealed n a 6 L Min Black Supplied in the component pack designed to be fitted...

Страница 11: ...ll at 110 mm centres Note If you are retro fitting your mixing valve onto existing pipework an Adjustable Elbow Pack is available if required refer to section Accessories 39 mm 3 For solid walls drill...

Страница 12: ...shed through before connection to the mixer Failure to do so may result in product malfunction and will not be covered under the guarantee 11 Fit the compression nuts and olives onto the pipework 12 A...

Страница 13: ...is to prevent the flexible hose from obstructing the shower controls refer to illustration 5 Mark the routes for the hot and cold supply pipework at 103 mm centres Hot Left Cold Right Note If it is n...

Страница 14: ...8 Carefully cut away the plasterboard and or brick work to a depth of between 56 and 76 mm from the finished wall surface Important Take care to stay within the marked out diameter otherwise the conc...

Страница 15: ...rom the pipes before proceeding 16 For solid wall installations or stud partition installations without rear access go to instruction 21 For stud partition installations with access to the rear of the...

Страница 16: ...all surface and should be fitted with the cutout in line with the outlet Installation 1 Draw a centre line between the inlet pipework and using the adjustable backplate as a template mark the position...

Страница 17: ...osition and type of flow regulator will vary by model For high pressure systems above 0 5 bar identify your model and install the flow regulator as illustrated where appropriate For gravity fed or oth...

Страница 18: ...er 3 Loosen the control lever grubscrew with the 2 5 mm hexagon key supplied and pull off the control lever 4 Unscrew the hub retaining screw with a 2 5 mm hexagon key Note Do not remove the hub 5 Ins...

Страница 19: ...ws retaining the valve on to the backplate If you require a Rada trained service engineer or agent refer to section Customer Services Fault Diagnosis Symptom Only hot or cold water from the mixer outl...

Страница 20: ...ter Note If the filter is damaged it must be replaced 7 Install the filters and reconnect the valve and fittings reverse of the above procedure 8 Turn on the water supplies and check for any leaks Con...

Страница 21: ...nts identified B 1663 162 Screw Pack components identified C 1663 168 Pipe Concealing Plate Adjustable Elbow V10 Contract 1663 335 Seal Pack components identified D 1663 167 Adjustable Elbow Assembly...

Страница 22: ...ied B 1663 162 Screw Pack components identified C 1663 189 Component Pack components identified D 1663 155 Filter Pack x2 1663 187 Backplate Assembly B C D 1663 188 Elbow Filter Pack x2 1663 186 Conce...

Страница 23: ...kit 1 25 m flexible hose clamp bracket assembly hose retaining ring and adjustable spray handset Available in chrome finish Suitable for connection to Exposed shower controls Rada Rigid Riser 1 1651...

Страница 24: ...product is us or our appointed representative Routine maintenance or replacement parts to comply with the requirements of the TMV2 or TMV3 healthcare schemes Accidental or wilful damage Products purc...

Отзывы: