6. Reversed Inlet Supplies Only:
a)
Remove the sealing plug using the ‘O’ key
(supplied) or a 12 mm hexagonal key.
b)
Remove the outlet nipple using the ‘O’ key
(supplied) or a 12 mm hexagonal key.
c)
Refit the sealing plug and outlet nipple in
the opposite outlets and tighten.
Note!
Make sure that the ‘O’ seals are
correctly fitted.
d)
Rotate the mixer 180°.
e)
If necessary, loosen the grubscrew on
each elbow using the 2.5 mm hexagon
key (supplied). Remove the elbows and
install on opposite sides. Retighten the
grubscrews.
Important!
Make sure that the elbows
are pushed fully onto the mixer before
tightening the grubscrews.
7.
Determine the position of the mixer and draw
around the
inside
of the concealing ring.
8.
Carefully cut away the plasterboard and/or
brick work to a depth of between 56 and 76 mm
from the
finished wall surface
.
Important!
Take care to stay within the marked
out diameter otherwise the concealing ring will
not seal.
9.
Fit the concealing ring over the mixer body,
then, holding the mixer level, central and
square in the hole, mark the positions of the
two backplate fixing holes on the wall.
10.
For solid walls drill two 6 mm holes for the
wall plugs. For other types of wall structure
alternative fixings may be required (not
supplied).
11.
Caution! It is essential at this point
that the supply pipework is thoroughly
flushed through before connection to the
mixer.
Failure to do so may result in product
malfunction and will not be covered under the
guarantee.
Sealing Plug
‘O’ Seal
Outlet Nipple
Top
Concealing Ring
Finished Wall
Surface
56 - 76 mm
Rear Mounting
Backplate Fixing Hole
Backplate Fixing
Hole