19
3.
Follow previous instructions
1-2
for
wall recess installation
.
Note!
The inlets accept rising or falling supplies, on thicker panels this may
require the inlet pipework to be configured with elbows or pipe bends immediately
prior to the inlet connections.
4.
Fit mounting bracket (407 88) to valve base using 2 screws (615 39) supplied.
If access is available it may be preferable to make the initial valve/pipework
connections prior to securing the valve to the panel.
5.
Mount valve securely into recess (see
Figure 5
), using drilled 212 mm hole
centres.
6.
Important!
Flush through the hot and cold supplies thoroughly before
connection to mixing valve
.
7.
Connect inlet and outlet pipework, checking that the hot and cold supplies have
been piped to the correct inlets, and check all connections are watertight.
8.
Plaster and tile, or finish as appropriate, up to the panel hole perimeter only,
and to a maximum thickness of 15 mm over the front face of the mounting
bracket. Protect the mixing valve and pipe connections during this process.
9.
Follow Rada 215-t3 bc instructions
7-10
for
wall recess installation
. Refer to
COMMISSIONING
.
Installation - Rada 215-t3 dk and 222-t3 dk
1.
The mixing valve is supported by its inlet and outlet pipework only, which must
be suitably and securely fastened.
2.
Inlets and outlet are external BSP union, intended to accept flat-faced connectors.
It is recommended that such union connections are used, so that the mixing
valve body can be readily removed from its pipework for maintenance purposes.
(UK market models:)
Three additional connectors are supplied (2 elbows, 1
straight, terminating in compression connections), which are interchangeable
to the inlets and outlet. Select the most appropriate configuration for the intended
installation, and, with nylon washers (636 10/11) in place, secure to valve body.
3.
Run inlet and outlet pipework to the mixing valve, checking that hot and cold
supplies have been piped to the correct inlets.
4. Important:
Flush through the hot and cold supplies thoroughly before
connection to mixing valve
.
5.
Connect inlet and outlet pipework, checking that the hot and cold supplies have
been piped to the correct inlets, and check all connections are watertight.