printf ("The NTP server is now running with IP address: ");
printf (nb_config_get("network.ntp.server0"));
The testing page offers an editor and an input field for optional arguments which can be used to perform
test runs of your script or test dedicated portions of it. Please note that you might need to quote argu-
ments as they will otherwise be separated by white-spaces.
/* arguments : schnick schnack "s c h n u c k" */
for (i = 0; i < argc ; i++) {
printf (" argv %d: %s\n", i, argv [i]);
}
/* generates:
* argv 0: /scripts/testrun
* argv 1: schnick
* argv 2: schnack
* argv 3: s c h n u c k
*/
In case of syntax errors, arena will usually print error messages as follows (indicating the line and pos-
ition where the parsing error occurred):
/scripts/testrun:2:10:FATAL: parse error, unexpected $, expecting ’;’
Note
It is now possible to upload SDK scripts into the Testing menu via browsing the required SDK
script and clicking on the "Run" button.
SDK Sample Application
As an introduction, you can step through a sample application, namely the SMS control script, which
implements remote control over short messages and can be used to send a system status back to the
sender. The source code is listed in the appendix.
Once enabled, you can send a message to the phone number associated with a SIM / modem. It
generally requires a password to be given on the first line and a command on the second, such as:
admin01
status
We strongly recommend to use authentication in order to avoid any unintended access, however you
may pass noauth as argument to disable it. You can then skip the first line containing the password.
Having a closer look to the script, you will see that you will also be able to restrict the list of permitted
senders. Please inspect the system log for troubleshooting any issues.
The following commands are supported:
status
An SMS with the following information will be returned
• Signal strength
109
© RACOM s.r.o. – M!DGE2 GPRS/UMTS/HSPA+/LTE router
Web Configuration
Содержание M!DGE2
Страница 2: ......
Страница 159: ...7 8 LOGOUT Log out from Web Manager 159 RACOM s r o M DGE2 GPRS UMTS HSPA LTE router Web Configuration ...
Страница 188: ...188 ...