12
DC Terminals
The DC terminals may ONLY be used for charging 12 volt automotive type batteries. The
terminals are colored red to identify the positive (+) terminal and black to identify the negative (-
) terminal. The battery must be connected to the generator DC terminals with the proper
polarity (battery positive to generator red terminal and battery negative to the generator black
terminal).
With DC Circuit Protector With DC Fuse
DC Circuit Protector (or DC Fuse)
The DC circuit protector(or DC Fuse) automatically shuts off the DC battery charging circuit when
the DC circuit is overloaded, when there is a problem with the battery, or the connections between
the battery and the generator are improper.
The indicator inside the DC circuit protector button will pop out to show that the DC circuit protector
has switched off. Wait a few minutes and push the button in to reset the DC circuit protector.
Connecting the battery cables:
1) Before connecting charging cables to a battery that is installed in a vehicle, disconnect the
vehicle’s grounded battery cable.
WARNING
The battery gives off explosive gases; keep spark, flames and cigarettes away. Provide adequate
ventilation when charging or using batteries.
2) Connect the positive (+) battery cable to the battery positive (+) terminal.
3) Connect the other end of the positive (+) battery cable to the generator.
4) Connect the negative (-) battery cable to the battery negative (-) terminal.
5) Connect the other end of the negative (-) battery cable to the generator.
6) Start the generator.
Содержание RAC3000