User Manual 1260-30
Installation Instructions 2-5
1260-30C
The following connections are required to configure the 1260-30
as a 1260-30C. To configure the 1260-30C from any other 1260-
30 configuration, remove all connections not on this list and install
22 gauge solid jumpers, listed below, unless otherwise specified.
COM 01 to E10
COM 02 to E02
COM 11 to E11
COM 12 to E12
COM 21 to E21
COM 22 to E22
COM 31 to E31
COM 32 to E32
COM 41 to E41
COM 42 to E42
COM 51 to E5l
COM 52 to E52
COM 61 to E61
COM 62 to E62
COM 71 to E71
COM 72 to E72
W1-1 to Wl-2
*E01-1 to EOO-1 Teflon stranded, 24 gauge, white
E01-2 to EOO-2 Teflon stranded, 24 gauge, black
*E23-1 to E1O-1 Teflon stranded, 24 gauge, white
E23-2 to ElO-2 Teflon stranded, 24 gauge, black
*E45-1 to E20-1 Teflon stranded, 24 gauge, white
E45-2 to E20-2 Teflon stranded, 24 gauge, black
*E67-1 to E30-1 Teflon stranded, 24 gauge, white
E67-2 to E30-2 Teflon stranded, 24 gauge, black
* Twisted Pair