INSTRUCTIONS
X17™
XFU 3-WAY FIELD ADJUSTABLE FLOODLIGHT
SELECTABLE PHOTOCELL INSTALLATION
RAB Lighting is committed to creating high-quality, affordable, well-designed and energy-efficient LED lighting and controls that make it easy for electricians to install
and end users to save energy. We’d love to hear your comments. Please call the Marketing Department at 888-RAB-1000 or email: [email protected]
TRUNNION MOUNT CONT.
To adjust the angle of the fi xture using the Trunnion (Fig. 6).
1. Loosen the
Pivot Bolts
and
Angle Locking Screws
.
2. Make appropriate wire connections per NEC in a approved
enclosure
(not included)
see Fig 12.
3. Adjust
Fixture
to desired angle
(Fig. 6)
.
4. Tighten
Pivot Bolts
and
Angle Locking Screws
.
SLIPFITTER MOUNT
1. Secure
Adapter Bracket
to
Housing
with (
2
)
Screws
(
provided
).
Feed
Housing
wires through
Adapter Bracket
as shown in
Fig.7.
2. Feed
Housing
wires through
Slipfi tter Bracket
and secure to
the
Adapter Bracket
with (
4
)
Screws
as shown in Fig. 8.
3. Continue wire feed through the
Slipfi tter Mount
and secure to
the
Slipfi tter Bracket
with
Locking Bolt
as shown in Fig .9.
4. Wire the
Housing
leads to supply wires using UL listed wire
connectors according to NEC and local codes
(Fig. 12).
5. To adjust
Housing
angle, loosen
Locking Bol
t and set
Housing
to desired angle.
6. Tighten the
Locking Bolt
to set angle.
Notice: 0° - 90° of angle adjustment.
Fig: 7
Adapter Bracket
Wires
Screw (
2
)
Housing
Fig: 8
Slipfi tter Bracket
Screw (
4
)
Adapter Bracket
Locking Bolt
Fig: 9
Slipfi tter Mount