RAB STEALTH STL360 Скачать руководство пользователя страница 6

INSTRUCTIONS

 

STEALTH STL360 INSTALLATION

RAB Lighting is committed to creating high-quality, affordable, well-designed and energy-efficient LED lighting and controls that make it easy for electricians to install

 

and end users to save energy. We’d love to hear your comments. Please call the Marketing Department at 888-RAB-1000 or email: [email protected]

STL360 KIT ASSEMBLY AND WIRING (

cont’d)

Assembly and Wiring.

1.  Attach the Universal Mounting Bar with the screws provided 

to the junction box. If you are attaching your STL360 kit to 
a surface mount weatherproof box, you must use with the 
mounting plate with gasket.

2.  Use the 

“S”

 shaped 

Hands Free Hanging Hook

 

(as shown in    

Fig 17)

 

to hold the 

CU4 EZ Plate

 during wiring.

3.  Bring power leads and sensor kit leads through holes in  

gasket and plate into junction box.

4.  Attach ground wire

(s) 

to junction box grounding screw.  

Connect as shown in wiring diagram, Fig. 18.

5.  Twist on wire nuts. Secure with electrical tape.
6.  Align 

CU4 EZ Plate

 and surface plate with gasket 

(for use with 

surface mounted junction boxes)

 to ensure proper seal. Tighten 

CU4 EZ Plate

 center screw 

(make sure O-Ring gasket is on the 

screw)

 to attach 

CU4 EZ Plate

 to the box.

7.  Insert plastic 

Finishing Cap

 in the center of the 

CU4 EZ Plate

 

for a weatherproof seal.

8.  Use silicone sealant around plate and all openings to ensure a 

weather proof seal.  Seal all unused conduit entries on surface 
junction box.

9.  Install lamps. Turn on power. Conduct walk test to adjust  

sensor response 

(Fig. 28)

.

Hood rests in notch 

on crossbar

Hands Free 

Hanging Hook

CU4 EZ Plate

Fig: 17

Fig: 18

To install STL360 Sensor with separately purchased Floodlights

1. 

Attach the threaded arm of each floodlight into the 

RAB CU4 

EZ Plate

 

(see diagram, Fig. 17).

2. 

S

crew the threaded arm of the sensor into the bottom hole of 

the 

CU4 EZ Plate

. Sensor should be below and as far away from 

the floodlights as possible.

3.  Attach the 

Universal Mounting Bar

 with the screws provided 

to the junction box. If you are attaching your STL360 kit to a 
surface mount weatherproof box, you must use the mounting 
plate with gasket.

4.  Use the “S” shaped

 Hands Free Hanging Hook

 to hold the 

CU4

 

EZ Plate

 during wiring.

5.  Bring power leads and sensor kit leads through holes in gasket 

into junction box.

6.  Attach ground wire

(s)

 to junction box grounding screw.

7.  Position 

CU4 EZ Plate 

and surface plate with  

gasket 

(required for mounting on surface junction boxes).

 

8.  Twist on wire nuts. Secure with electrical tape.
9.  Make sure all unused openings in 

CU4 EZ Plate

 are closed  

with plugs

 (provided)

.

10.  Use silicone sealant around plate and all openings to ensure a 

weather proof seal. Seal all unused conduit entries on surface 
junction box.

11.  Screw in lamps. Turn on power. 
12.  Conduct walk test to adjust sensor response 

(Fig. 28).

Содержание STEALTH STL360

Страница 1: ...or garage door openers Sensor functions best when the direction of expected movement is across its detection pattern not towards the sensor Mount 6 10 high for optimum range and detection WARNING RIS...

Страница 2: ...ghts remain on as long as there is movement within the protection zone Once the zone is vacated lights can be adjusted to remain on approximately 5 seconds up to 12 minutes Since the lights are on onl...

Страница 3: ...ge an area does STL360 protect Two powerful detectors combine to give the STL360 180 x 60 long forward range plus superb 360 downward detection below and to all sides as shown in Fig 3 Di cult locatio...

Страница 4: ...mounted level from side to side and pointed at the area where you desire coverage If tilted part of the detection zone may be high in the air over people s heads as shown in Fig 12 Fig 8 Fig 11 Fig 1...

Страница 5: ...location as shown in Fig 14 Mounting and Wiring Red pigtail is only used to switch remote or additional fixtures as shown in Fig 16 STL360 floodlight kits come pre wired and assembled on the RAB CU4 E...

Страница 6: ...silicone sealant around plate and all openings to ensure a weather proof seal Seal all unused conduit entries on surface junction box 9 Install lamps Turn on power Conduct walk test to adjust sensor...

Страница 7: ...ell For night only operation turn the knob completely counterclockwise to the MOON symbol For 24 hour operation turn the knob all the way clockwise to the MOON SUN symbol Adjust counterclockwise to ha...

Страница 8: ...g 25 Fig 26 Evening Timer Mode Keeps lights on for 1 8 hours after dusk Sensor then reverts to Automatic Mode until dawn If you set the Evening Timer Mode during daylight the sensor will be prepared t...

Страница 9: ...ual Override while the sensor is set to 24 hour operation photocell set to MOON SUN lights will come on and remain on continuously Lights will not turn o at dawn Fig 27 Fig 28 WALK TESTING Ready for M...

Страница 10: ...below Solution 1 Aim sensor away from movement or 2 Mask lens in the direction of the source 3 Lower sensitivity control setting Lights Turn On and Off Inappropriately 1 Make sure that the sensor is i...

Страница 11: ...The sensor s photocell may detect the light and deactivate daylight If you desire the sensor to operate in higher ambient light levels turn the SUN MOON control knob counter clockwise toward the sun s...

Страница 12: ...l from side to side and pointed at the area you desire If unit is tilted part of the detection zone may be high in the air over people s heads Solution Position sensor exactly level from side to side...