
INSTRUCTIONS
STEALTH STL360 INSTALLATION
RAB Lighting is committed to creating high-quality, aff ordable, well-designed and energy-effi cient LED lighting and controls that make it easy for electricians to install
and end users to save energy. We’d love to hear your comments. Please call the Marketing Department at 888-RAB-1000 or email: [email protected]
INSTALLATION (
cont’d)
Locations near roads
(cont’d)
Make sure that sensor is not aimed at traffi c. The sensor
should be aimed down so that the maximum range of
the sensor ends at least 20’ from the road. This will avoid
detection of passing trucks and cars or the air currents
they create as shown in
Fig 11
.
Mount Level
The sensor should be mounted level from side to side and
pointed at the area where you desire coverage. If tilted,
part of the detection zone may be high in the air over
people’s heads as shown in
Fig 12
.
Fig: 8
Fig: 11
Fig: 12
Light vs. Sensor Position
Make sure sensor and lights are mounted fi rmly. If they move when
touched, tighten all screws.
Make sure heat from lights is not triggering sensor. Sensor must be
located below and as far away as possible from its lights as shown
in
Fig 8
.
Wrong
OK!
Fig: 9
Fig: 10
Locations near roads
Cars and passing traffi c may activate the sensor if it is aimed at
the road.
To improve performance in diffi cult locations
Reduce sensitivity by turning the SENS knob counterclockwise
as shown in
Fig 9.
Mask the lens in the direction of traffi c using the
Lens Mask
provided
(
Lens Mask
can be broken along lines to desired size)
as
shown in
Fig 10
.
Lens Mask
(included)
20
'
safety zone
OK!
WRONG
OK!