RAB GOTCHA PLUS GT500 Скачать руководство пользователя страница 6

INSTRUCTIONS

GOTCHA

®

 PLUS INSTALLATION

RAB Lighting is committed to creating high-quality, aff ordable, well-designed and energy-effi  cient LED lighting and controls that make it easy for electricians to install

and end users to save energy. We’d love to hear your comments. Please call the Marketing Department at 888-RAB-1000 or email: marketing@rablighting.com

LIGHTS TURN ON AND OFF INCORRECTLY

1.  Make sure the sensor is installed on its own dedicated circuit free 

of motor loads such as HVAC equipment, kitchen appliances or 
garage door openers.

2.  It is not recommended to wire sensors in parallel. More than 

one sensor wired together makes them diffi  cult to troubleshoot. 
Disconnect multiple sensors and test separately.

3.  Keep all people completely out of the detection pattern to make 

sure the sensor is not detecting them.

4.  Make sure sensor is located below and as far as possible from its 

lights. Heat from the lights may trigger the sensor.

5.  Make sure lights are not visible from or refl ecting back into 

sensor. Check for white or refl ective surfaces close to the sensor.

6.  Heavy rain, snow or high winds may activate the sensor 

occasionally.

TROUBLESHOOTING 

(cont’d)

TROUBLESHOOTING 

(cont’d)

Solution: Move sensor below and away from the lights.

Solution: Aim sensor away from lights and refl ective objects or 
mask the lens in the direction of the light or refl ection.

Solution:  Reduce sensitivity control settings, mount in a 
more protected area and/or mask the lens if this is a constant 
problem.

TOLLFREE TECHNICAL ASSISTANCE

If you need technical assistance, please do the following:
1.  Re-read the 

Technical Tips

 sections of this manual.

2.  Call the Tech Help Line at 888 722-1000, 8AM to 4PM Eastern 

Time M-F and we will be glad to help you. Before you call, please 
have the following information handy:
• Catalog number of your unit;
• Wattage, types and locations of lights connected to the sensor;
• The electrical circuit on which the sensor is installed…
  what else does it feed? How is the sensor power switched?
• This installation manual.

Note: 

RAB Lighting cannot give electrical wiring instructions by phone. 

Please consult a qualifi ed electrician.

Note:

 These instructions do not cover all details or variations in equipment nor do they provide for every possible situation during installation operation or maintenance.

GOTCHA IN 0620

Easy Answers

rablighting.com

Visit our website for product info

Tech Help Line

Call our experts: 888 722-1000

e-mail

Answered promptly - sales@rablighting.com

Free Lighting Layouts

Answered online or by request

© 2020 RAB LIGHTING Inc.

Northvale, New Jersey 07647 USA

RAB WARRANTY:

 RAB’s warranty is subject to all terms and conditions found at rablighting.com/warranty.

7.  Make sure sensor is not aimed within 30’ of a road or sidewalk. 

Passing cars will activate sensor.

8.  Self ballasted PL lamps may cause cycling

 (on-off )

.

9.  Check solutions 1, 2, 3, 5 & 6 under “Lights Do Not Turn Off ” 

(Pg. 5)

.

Solution:  Mask the top of the lens to reduce Detection 
Pattern Length.

Содержание GOTCHA PLUS GT500

Страница 1: ...arp objects SPECIFICATIONS CONTENTS GT500 Voltage 120V 277VAC 60Hz UL Listing Suitable for wet locations raintight Time Adjustment 5 sec to 15 min Test Mode Set Time Adjustment Knob on sensor to Test Mode Switching Capacity 500W 120VAC Tungsten 500W 277VAC Tungsten 600W 120VAC Electronic Ballast LED 1350W 277VAC Electronic Ballast LED Power Consumption 4 Watts Surge Protection 6 kV Operating Tempe...

Страница 2: ...nd rectangular or octagonal surface or recessed box 1 Attach Cross Bar to Surface Junction Box using three bar screws supplied Fig 4 2 Bring sensor wires through the Surface Adaptor Plate 3 Make connections to the supply wires in the junction box according to the Basic Kit Wiring diagram on pg 5 4 Push connected wires into the Surface Junction box 5 Place the O Ring over the 1 4 20 Screw and inser...

Страница 3: ...r the experienced installer because it becomes difficult to troubleshoot Single sensors that control their own lights pinpoint movement more accurately and operate better Fig 9 Fig 7 Fig 8 Fig 9 3 FactoryPre wired WireDuring Installation WIRING Cautions All wiring MUST comply with local electrical codes and should be installed by qualified electrician Read entire Installation Manual before proceed...

Страница 4: ... in its Detection Zone Once the Detection Zone is tested adjust the sensor Time control to desired standby time PICKING A LOCATION AIMING TESTING WALK TESTING Fig 11 4 70ft 50ft 8 10ft 50ft Detection Pattern Start Finish To keep lights on at night flip the wall switch two times OFF ON OFF ON within 5 seconds Sensor resets to auto mode after 6 hours Switch the power ON and OFF once OFF ON quickly t...

Страница 5: ...URN ON 1 Check that lamps and fixtures work Compare wiring to the Wiring Diagram in this manual Check that the power is on 2 Check that lights from other sources such as adjacent porch lights garden lights streetlights or lights from inside the house are not in the sensor s view See 1 under Lights Turn Off Too Quickly 3 Was sensor wired hot If so circuitry may have been damaged 4 If sensor is pain...

Страница 6: ...nsitivity control settings mount in a more protected area and or mask the lens if this is a constant problem TOLL FREE TECHNICAL ASSISTANCE If you need technical assistance please do the following 1 Re read the Technical Tips sections of this manual 2 Call the Tech Help Line at 888 722 1000 8AM to 4PM Eastern Time M F and we will be glad to help you Before you call please have the following inform...