WP1FC Full Cut-off INSTALLATION INSTRUCTIONS
PHOTOCELL INSTALLATION
A PHOTOCELL MAY BE INSTALLED IN THE FIELD.
1. Remove door and reflector
2. Remove close up plug on top of fixture
3. Install photocell and wire as per diagram
RE-LAMPING
CAUTION:
Prior to installing, check that the lamp is of proper type and wattage. Observe lamp manufacturer’s
recommendations on lamp operation, burning position and ballast type.
1. Disconnect power
2. Make sure fixture and lamp are cool enough to touch
3. Loosen two screws holding door frame
4. Open by swinging door to the left, letting hinge hold door
5. Replace lamp
6. Close door and tighten screws
REPLACEMENT LAMPS
METAL HALIDE
ANSI
HIGH PRESSURE SODIUM
ANSI
FLUORESCENT
Wattage
Catalog#
Code
Wattage
Catalog#
Code
Wattage
Catalog#
50PS
LMH50
M110
35
LHPS35
S76
42
LCFL42
70PS
LMH70
M98
50
LHPS50
S68
100PS
LMH100
M90
70
LHPS70
S62
100
LHPS100
S54
150
LHPS150
S55
CLEANING
Caution:
Be sure fixture temperature is cool enough to touch. Be sure power is off.
Clean reflector and refractor with a cloth moistened with non abrasive glass cleaning solution.
TROUBLESHOOTING CHECKLIST
Check that:
1. Proper lamp is installed. Lamp is not faulty
2. Line voltage at the fixture is correct
3. Fixture is wired correctly
4. Fixture is grounded correctly
THESE INSTRUCTIONS
DO NOT
COVER ALL DETAILS OR VARIATIONS IN EQUIPMENT, NOR DO THEY PROVIDE FOR EVERY
POSSIBLE CONTINGENCY TO BE MET IN CONNECTION WITH INSTALLATION, OPERATION OR MAINTENANCE.
EASY INSTALLATION & PRODUCT HELP
©
RAB
Lighting, Inc.
170 Ludlow Avenue Northvale, NJ 07647 USA
1/06
RAB
MAKES
IT
EASY!
Info on Demand
������������������
������������
rabweb.com
�����������������
����������������
Tech Help Line
����������������
������������
Toll Free Fax
�����������������
������������
�����������������
����������������
“COM”
PHOTOCELL
WP2FC
WP1FC