1.  Preliminary Instructions

• General Warnings

This  equipment  should  only  be  operated,  installed  and 

maintained by “trained” or “qualified” personnel who are familiar 

with risks involved in working on electric and electronic circuits. 
“Trained” means personnel who have technical knowledge of 
equipment operation and who are responsible for their own 

safety and that of other unqualified personnel placed under 

their supervision when working on the equipment. 

 

“Qualified”  means  personnel  who  are  trained  in  and 
experienced  with  equipment  operation  and  who  are 

responsible for their own safety and that of other unqualified 

personnel placed under their supervision when working on 
the equipment. 

 WARNING: Residual voltage may be present inside 

the equipment even when the ON/OFF switch is set to 

Off.  Before  servicing  the  equipment,  disconnect  the 

power  cord  or  switch  off  the  main  power  panel  and 

make sure the safety earth connection is connected.

 

Some  service  situations  may  require  inspecting  the 

equipment with live circuits. Only trained and qualified 

personnel may work on the equipment live and shall be 

assisted by a trained person who shall keep ready to 

disconnect power supply at need.

R.V.R. Elettronica S.p.A.

  shall not be liable for injury to 

persons or damage to property resulting from improper use 

or operation by trained/untrained and qualified/unqualified 

persons.

 WARNING: The equipment is not water resistant. 

Any water entering the enclosure might impair proper 

operation.  To  prevent  the  risk  of  electrical  shock  or 

fire, do not expose this equipment to rain, dripping or 

moisture.

Please observe local codes and fire prevention rules when 

installing and operating this equipment.

  WARNING:  This  equipment  contains  exposed 

live parts involving an electrical shock hazard. Always 

disconnect power supply before removing any covers 

or other parts of the equipment.

Ventilation slits and holes are provided to ensure reliable 
operation  and  prevent  overheating;  do  not  obstruct  or 
cover these slits. Do not obstruct the ventilation slits under 
any circumstances. The product must not be incorporated 
in  a  rack  unless  adequate  ventilation  is  provided  or  the 
manufacturer’s instructions are followed closely.

  WARNING:  This  equipment  can  radiate 

radiofrequency energy and, if not installed in compliance 

with  manual  instructions  and  applicable  regulations, 

may cause interference with radio communications.

  WARNING:  This  equipment  is  fitted  with  earth 

connections both in the power cord and for the chassis. 

Make sure both are properly connected.

Operation of this equipment in a residential area may cause 
radio interference, in which case the user may be required 
to take adequate measures.

The specifications and data contained herein are provided 

for information only and are subject to changes without prior 
notice. 

R.V.R. Elettronica S.p.A.

 disclaims all warranties, 

express  or  implied.While  R.V.R.  Elettronica  S.p.A. 
attempts to provide accurate information, it cannot accept 
responsibility or liability for any errors or inaccuracies in this 
manual, including the products and the software described 
herein. 

R.V.R. Elettronica S.p.A.

 reserves the right to make 

changes to equipment design and/or specifications and to 

this manual at any time without prior notice.

• Notice concerning product intended purpose and use 

limitations.

This product is a radio transmitter suitable for frequency-
modulation  audio  radio  broadcasting.  Its  operating 
frequencies are not harmonised in designated user countries. 
B e f o r e   o p e r a t i n g   t h i s   e q u i p m e n t ,   u s e r   m u s t 
obtain  a  licence  to  use  radio  spectrum  from  the 
competent  authority  in  the  designated  user  country. 
Operating  frequency,  transmitter  power  and  other 
characteristics  of  the  transmission  system  are  subject  to 

restrictions as specified in the licence.

 

2.  Warranty

La 

R.V.R. Elettronica S.p.A.

 warrants this product to be free 

from defects in workmanship and its proper operation subject 
to the limitations set forth in the supplied Terms and Conditions. 
Please read the Terms and Conditions carefully, as purchase 
of the product or acceptance of the order acknowledgement 
imply  acceptance  of  the  Terms  and  Conditions. 
For the latest updated terms and conditions, please visit our web 

site at WWW.RVR.IT. The web site may be modified, removed 

or updated for any reason whatsoever without prior notice. 
The  warranty  will  become  null  and  void  in  the  event  the 
product  enclosure  is  opened,  the  product  is  physically 
damaged, is repaired by unauthorised persons or is used for 
purposes other than its intended use, as well as in the event 
of improper use, unauthorised changes or neglect.     
In the event a defect is found, follow this procedure:

Contact the seller or distributor who sold the equipment; 
provide a description of the problem or malfunction for 

the event a quick fix is available.  

Sellers  and  Distributors  can  provide  the  necessary 
information to troubleshoot the most frequently encountered 
problems.  Normally,  Sellers  and  Distributors  can  offer  a 
faster repair service than the Manufacturer would. Please 
note  that  Sellers  can  pinpoint  problems  due  to  wrong 
installation.

If your Seller cannot help you, contact 

R.V.R. Elettronica 

S.p.A.

 and describe the problem; if our staff deems it 

appropriate, you will receive an authorisation to return 
the equipment along with suitable instructions;

When  you  have  received  the  authorisation,  you  may 
return the unit. Pack the unit carefully before shipment; 
use the original packaging whenever possible and seal 
the package perfectly. The customer bears all risks of 
loss (i.e., R.V.R. shall not be liable for loss or damage) 
until the package reaches the R.V.R. factory. For this 
reason, we recommend insuring the goods for their full 
value. Returns must be sent on a C.I.F. basis (PREPAID) 

to the address stated on the authorisation as specified 

by the R.V.R. Service Manager.

IMPORTANT

The symbol of lightning inside a triangle placed on the product, evidences the operations for 
which is necessary gave it full attention to avoid risk of electric shocks. 

The symbol of exclamation mark inside a triangle placed on the product, informs the user 
about the presence of instructions inside the manual that accompanies the equipment, im-

portant for the efficacy and the maintenance (repairs).

Содержание URPR/ MIC

Страница 1: ...URPT MIC URPR MIC USER MANUAL VOLUME1 Manufactured by R V R ELETTRONICA S p A Italy...

Страница 2: ...part of this manual may be reproduced memorized or transmitted in any form or by any means electronic or mechanic including photocopying recording or by any informa tion storage and retrieval system...

Страница 3: ...RPR MIC Frontal Panel Description 11 4 7 URPR MIC Rear Panel Description 12 4 8 URPR MIC Connector Description 13 4 9 URPT MIC Technical Description 15 4 10 URPR MIC Technical Description 17 5 URPT MI...

Страница 4: ...ii User Manual Rev 1 1 29 06 12 URPT MIC URPR MIC ELETTRONICA This page was intentionally left blank...

Страница 5: ...liability for any errors or inaccuracies in this manual including the products and the software described herein R V R Elettronica S p A reserves the right to make changes to equipment design and or s...

Страница 6: ...e 3 Figure 4 Figure 5 One rescuer give 2 quick rescue breaths after each 15 compressions Two rescuers one rescue breath after each 5 compressions Do not stop chest compressions while giving artificial...

Страница 7: ...low enviromental impact supplies by batteries or photovoltaic panels 4 1 Unpacking The package contains 1 URPT MIC and or URPR MIC 1 User Manual 1 Mains power cable The following accessories are also...

Страница 8: ...connector for connection to external machine or rescue battery In the standard version of the URPR MIC the demodulated signal is available in the MPX form that is to say the complete basis signal band...

Страница 9: ...requency Setting of the muting threshold Measurement and display of the working parameters of the receiver Communications with external devices such as programming systems or telemetry systems via SER...

Страница 10: ...ne jack 16 HEADPHONES Jack connector for headphones Dual mono output 17 DISPLAY Liquid crystals display 19 ENCODER ON Red LED light on when the 27 Hz subtone is enabled 19 POWER ON Green LED light on...

Страница 11: ...OWER ON OFF switch 34 ESC Push button to exit from a menu 35 Push button to move in the menu system and to modify the parameters 36 Push button to move in the menu system and to modify the parameters...

Страница 12: ...pply 2 R F OUTPUT RF output connector N type 50 3 ACCESSORY DB15 male connector for interconnection with other devices i e external battery 4 FUSE BLOCK Fuse carrier Use a screwdriver to access the fu...

Страница 13: ...good 8 GND Ground 9 GND Ground 10 Ext AGC RFL IN Ext signal 1 12V for power limitation AGC 11 Reserved 12 IPA Tlm ANL OUT PA power supply current 3 9V F S 13 RFL Tlm ANL OUT Reflected power 3 9V F S 1...

Страница 14: ...10 42 User Manual Rev 1 0 29 06 12 URPT MIC URPR MIC ELETTRONICA 4 5 3 INP 1 2 3 4 Type XLR Female 1 GND 2 Positive 3 Negative...

Страница 15: ...ay contrast adjusting trimmer 11 OUT 1 R XLR balanced connector for MONO output 1 or RIGHT 12 ADJ 12dBu Level adjusting trimmer from 12 to 12 dBu for MONO output 1 or RIGHT 13 OUT 1 R XLR balanced con...

Страница 16: ...supply 2 R F INPUT RF input connector N type 50 3 ACCESSORY DB15 male connector for interconnection with other devices i e external battery 4 FUSE BLOCK Fuse carrier Use a screwdriver to access the fu...

Страница 17: ...reshold 8 GND Ground 9 GND Ground 10 Not Used 11 SCL IIC Bus 12 OUT3 Level 13 OUT1 Level 14 On cmd DIG IN One grounded pulse 500 ms enables the AF 15 OFF cmd DIG IN One grounded pulse 500 ms disables...

Страница 18: ...14 42 User Manual Rev 1 0 29 06 12 URPT MIC URPR MIC ELETTRONICA 4 8 3 OUT 1 R 2 L Type XLR Male 1 GND 2 Positive 3 Negative...

Страница 19: ...response 40 Hz 15 KHz Total Harmonic Distortion THD N 40 Hz 15 KHz Stereo separation Connector Type Impedance Connector Type Impedance Connector Type Impedance Connector Type Impedance Input 4 XLR F...

Страница 20: ...z modulation URPT MIC option EN 60215 1989 EN60215 A1 1992 07 EN60215 A2 1994 09 EN 301 489 1 V1 4 1 2002 08 EN 301 489 11 V1 2 1 2002 11 EN 302 018 2 V1 2 1 2005 06 MECHANICAL SPECIFICATION 355x85x29...

Страница 21: ...on Connector Phisical Dimensions W x H x D Weight SAFETY EMC Spectrum Optimization FM Alphanumerical LCD 2 x 16 from 10 C to 50 C URPR MIC B Value GENERALS B10 135 185 B20 215 265 B30 300 350 B40 430...

Страница 22: ...he relevant sections for additional details IMPORTANT When configuring and testing the transmitter in which the equipment is integrated be sure to have the Final Test Table supplied with the equipment...

Страница 23: ...he voltage selection block of the power supply located under the equipment is set to the appropriate voltage change setting as required The exciter through the ACCESSORY connector has an input for ext...

Страница 24: ...from 230V to 115V position on the AC power supply card Figure 5 1 switch to change the voltage on the underside URPT MIC 5 1 3 Connections Connect the RF output of the transmitter to the antenna cabl...

Страница 25: ...power set to upper limit unless otherwise specified by customer 5 2 1 Power on When you have performed all of the connections described in the previous paragraph power on the exciter using the suitabl...

Страница 26: ...any adjustments you make using the keys and provides a graphic indication of how much power supply will be delivered the moment you return to Pwr On state ENTER to bring the selection to ON 5 3 Operat...

Страница 27: ...state Press ESC to call up the selection screen menu 3 Highlight Fnc and press ENTER to confirm and access the selected menu menu 4 If PWR is set to OFF i e power output is disabled move cursor to PWR...

Страница 28: ...ine LCD display where a set of menus is shown An overall view of the machine s menus is given in figure One of the following symbols may be present on the left side of the display depending on the cas...

Страница 29: ...Miscellaneous Menu Menu Menu Versions Menu Menu 8 Menu 8 Figura 5 2 When the display is off touching any key will turn on backlighting When the display is on pressing the ESC button from the default...

Страница 30: ...e simply select item PgD or PgR and edit its value using the and buttons finally press ENTER to confirm Menu 4 Pwr Enables ON or disables OFF exciter power output Mod Modifies modulation display toggl...

Страница 31: ...four lines that can be scrolled using the and buttons and shows the readings relating to final power stage Menu 6 Note that these are readings rather than settings and cannot be edited note the empty...

Страница 32: ...e time out the previous frequency setting is retained Clp Enables ON or disables OFF the clipper Aux Enables ON or disables OFF the external audio if present Enc Enables ON or disables OFF the sub ton...

Страница 33: ...5 4 5 Version Menu Vrs This screen holds equipment version release information Menu 8 Note that these are readings rather than settings and cannot be edited note the empty arrow Rel Firmware release i...

Страница 34: ...features and capabilities Please see the relevant sections for additional details IMPORTANT When configuring and testing the receiver in which the equipment is integrated be sure to have the Final Te...

Страница 35: ...e voltage selection block of the power supply located under the equipment is set to the appropriate voltage change setting as required The receiver through theACCESSORY connector has an input for exte...

Страница 36: ...eath may result Ensure that the POWER switch on the front panel is set to OFF The receiver has a switch that interrupts completely the mains power of equipment Connect the mains power cable to the MAI...

Страница 37: ...aph power on the receiver using the suitable power switch on the front and rear panel 6 2 2 How to enable the AF output Check the state of the AF output power by the Fnc menu If it is set to OFF press...

Страница 38: ...ves the instantaneous reading of the muting level Press button to increase level press to decrease it When you have achieved the desired level press ENTER to confirm and exit the default menu Please n...

Страница 39: ...y messages NOTE Standard factory settings are output power set to upper limit unless otherwise specified by customer and OFF 6 4 Management Firmware The machine is provided with a two line LCD display...

Страница 40: ...Menu 6 Menu Menu Version Menu Figure 6 1 When the display is off touching any key will turn on backlighting When the display is on pressing the ESC button from the default menu menu 1 calls up the se...

Страница 41: ...N or disables OFF receiver muting Mod Modifies modulation display toggles between x1 and x10 In x10 mode instantaneous deviation indication is multiplied by a factor of 10 and the bar meter on the def...

Страница 42: ...s ESC or let the preset time time out the previous frequency setting is retained RF Visualization of the reading of RF level Att Adjusting of the attenuation on input expressed in dB 6 4 3 Audio Menu...

Страница 43: ...6 4 4 Version Menu Vrs This screen holds equipment version release information Menu 7 Note that these are readings rather than settings and cannot be edited note the empty arrow Rel Firmware release i...

Страница 44: ...hrough connectors so as to make maintenance and any required module replacement easier 7 1 URPT MIC Upper View The figure below shows the equipment upper view with the various components pointed out F...

Страница 45: ...ure below shows the equipment upper view with the various components pointed out Figure 7 2 1 Panel Card 2 70MHz IF Audio Card 3 Front End and VCO Card 4 IF NARROW B Converter Card 5 10 7 MHz Band Pas...

Страница 46: ...42 42 User Manual Rev 1 0 29 06 12 URPT MIC URPR MIC ELETTRONICA This page was intentionally left blank...

Страница 47: ...____________________________________________________________ ______________________________________________________________________________ ____________________________________________________________...

Страница 48: ...104 e mail info rvr it web http www rvr it The RVR Logo and others referenced RVR products and services are trademarks of RVR Elettronica S p A in Italy other countries or both RVR 1998 all rights res...

Отзывы: