15 / 30
User Manual
Rev. 1.2 - 21/01/11
TEX2000LCD
75 kHz. This display mode is convenient when you wish to display low
deviation levels, such as those caused by pilot tone or subcarriers.
PgD
Modifies Power Good threshold for forward power. The Power Good
rate is a percent of equipment rated power, that is 2000W, not of forward
output power. This means that this threshold set at 50% will give 1000
W, respectively, regardless of set power level. The Power Good feature
enables output power control and reporting. When output power drops
below set Power Good threshold, the equipment changes the state of
pin [7] of the DB15 “Remote” connector located on the rear panel.
PgR
Modifies Power Good threshold for reflected power. The Power Good
rate is a percent of equipment rated power, that is 200 W, not of reflected
output power. This means that this threshold set at 10%, will give 5W
regardless of set power level. The Power Good feature enables output
power control and alarm management.
NOTE: This alarma does not trip any contacts in the DB15 “Remote” connector
and is only available in systems equipped with telemetry.
5.4.2 Power menu (Pwr)
This screen holds all readings related to equipment output power:
Menu 5
Fwd
Forward power reading.
Rfl
Reflected power reading.
Note that these are readings, rather than settings, and cannot be edited (note
the empy triangle). To change power setting, go to the default menu as outlined
earlier.
5.4.3 Power Amplifier (P.A) Menu
This screen is made up of four lines that can be scrolled using the
and
buttons and shows the readings relating to final power stage: