23 / 30
User Manual
Rev. 1.2 - 21/01/11
TEX2000LCD
6.3.4 Remote
Type: Female DB15
Pin Name
Type
Meaning
1
Interlock
IN
By passes power if closed at GND
2
Ext AGC FWD
IN
Ext. signal,1-12V, for forward
power limitation (AGC)
3
GND
Ground
4
SDA IIC
I/O
IIC communication serial data
5
VPA Tlm
ANL OUT
PA power supply voltage: 3.9V F.S.
6
FWD Tlm
ANL OUT
Forward power: 3.9V F.S.
7
Power Good
DIG OUT
Open collector, enabled whenpower
exceeds the set threshold (chap.
5.4.1)
8
GND
Ground
9
GND
Ground
10 Ext AGC RFL
IN
Ext. signal,1-12V, for reflected
power limitation (AGC)
11
SCL IIC
I/O
IIC communication clock
12
IPA Tlm
ANL OUT
PA power supply current: 3.9V F.S.
13 RFL Tlm
ANL OUT
Reflected power: 3.9V F.S.
14
On cmd
DIG IN
One grounded pulse (500 ms)
enables power supply
15
OFF cmd
DIG IN
One grounded pulse (500 ms)
disables power supply