Response timeout
Shows and sets waiting time for receiving the response frame for the
serial protocol.
Uart Baud
Shows and sets serial protocol speed.
5.3.6.2 Alarms menu
General settings
Run time
DEVICE
ALARMS
Enable alarms
61
Enable send Mail
1
Enable Recive Mail
0
Destination 1
Destination 2
NONE
Destination 3
NONE
Destination 4
NONE
Subject
TEX-ALARM
SECURITY
Update
Menu 12
This page allows configuration of the signal for alarms of the exciter connected to
RDMODWEB
interface.
Enable alarms
Shows and sets alarm presence sampling time, in seconds. If the value
is equal to 0, alarm check task is disabled.
Enable send mail
Enables (0) or disables (1) mail output after alarms.
Enable receive mail
Enables (0) or disables (1) control message reception.
Destination X
Shows and sets the list of addresses to which alarm warning mail
messages shall be sent. Maximum 4 different addresses can be
saved.
Subject
Shows and sets the description of the “subject” field of the mail.