5.3.2 Power Menu (Pwr)
This screen holds all readings related to machine output power:
Menu 5
Note that these are readings, rather than settings, and cannot be edited (note
the empty arrow). To change power setting, go to the
default menu
(menu 1) as
outlined earlier.
Fwd
Forward power reading.
Rfl
Reflected power reading.
Inp
Input power reading.
5.3.3 Menù Power Amplifier (P.A)
This screen is made up of four lines that can be scrolled using the buttons and
, shows the readings relating to final power stage:
Menu 6
Note that these are readings, rather than settings, and cannot be edited (note the
empty arrow).
VPA
Voltage supplied to amplifier module.
IPA
Current absorbed to amplifier module.
Eff
Efficiency based on ratio of forward power to amplifier module power
in percent ( FWD PWR/(Vpa x Ipa) % ).
Tmp
Machine internal temperature.