14
/ 48
User Manual
Rev. 3.0 - 21/03/18
PJ5000U-K
L N PE
If transmitter require three-phase power with 3F (black, brown and grey) + N
3F (black, brown and grey) + N
(blue) + GND (green yellow), keep in mind this requirement to connect to your
, keep in mind this requirement to connect to your
distribution board.
R S T N PE
Note:
the mains must be equipped with adequate earth connection properly
connected to the equipment. This is a pre-requisite for ensuring operator safety
and correct operation.
The following table shows the recommended cable cross-sections:
CONNECTOR
THREE-PHASE
CABLE SECTION
SINGLE-PHASE
CABLE SECTION
L
/
Ø 6mm
R
Ø 4mm
/
S
Ø 4mm
/
T
Ø 4mm
/
N
Ø 4mm
Ø 6mm
PE
Ø 4mm
Ø 6mm
Tipically the distribution board contains the thermal-magnetic circuit breakers for
each amplifier included in the system and one for service.