30 / 38
User Manual
Rev. 1.0 - 29/06/09
PJ2500M-C, PJ3000HE, PJ3500M-C,
PJ4000U-K & PJ5000U-K
8.1.1 Single-Phase Wiring
WARNING:
the power supply in single-phase can be used only with 208/230V
voltage.
For the single-phase, the configuration of the external power supply plug must
have the following characteristics:
• PIN1 of the main connector is connected to Neutral wire.
• PIN2 of the main connector is connected to Phase wire and internally connected
to PIN3 by Ø 6mm wire.
• PIN3 of the main connector is internally connected to PIN2 and to PIN4 by Ø
6mm wire.
• PIN4 of the main connector is internally connected to PIN3 by Ø 6mm wire.
• PIN5 is directly wired to ground.