The limit voltages of the quantities monitored by the warning thresholds for are
the follows:
•
Forward Power
5000 W
(mod.
PJ5000U-K
)
•
Forward Power
4000 W
(mod.
PJ4000U-K
)
•
Forward Power
3500 W
(mod.
PJ3500M-C
)
•
Forward Power
3000 W
(mod.
PJ3000HE
)
•
Forward Power
2500 W
(mod.
PJ2500M-C
)
•
Reflected Power
200 W
Proceed as follows to change the values of the warning thresholds:
•
Select the line to be changed (with the UP and DOWN keys)
• Press the ENTER key
• Change the threshold value (UP and DOWN keys)
• Press ENTER to confirm
The figure below shows a configuration example of this menu.
In this example the alarm thresholds are as follows:
•
PwrGd1
4000 W
(80% x 5000 W x mod.
PJ5000U-K
)
3200 W
(80% x 4000 W x mod.
PJ4000U-K
)
2800 W
(80% x 3500 W x mod.
PJ3500M-C
)
2400 W
(80% x 3000 W x mod.
PJ3000HE
)
2000 W
(80% x 2500 W x mod.
PJ2500M-C
)
•
PwtGd2
2500 W
(50% x 5000 W x mod.
PJ5000U-K
)
2000 W
(50% x 4000 W x mod.
PJ4000U-K
)
1750 W
(50% x 3500 W x mod.
PJ2500M-C
)
1500 W
(50% x 3000 W x mod.
PJ3000HE
)
1250 W
(50% x 2500 W x mod.
PJ2500M-C
)
•
RflWar
80 W
(40% x 200 W)
5.3.5 Alarm Menu
This menu provides information about the status of the amplifier’s built-in protection
system.