1
/ 32
User Manual
Rev. 1.0 - 29/11/12
TEX30/50/100/150/300LCD
ELETTRONICA
NOTE: This feature prevents the equipment from delivering maximum power
as soon as output is enabled from menu 4, or in the event the equipment is
already set to
ON
when you energise it.
2) Ensure that the equipment is not in a locked-out state. Press
ESC
to call up
the selection screen (menu 3). Highlight
Fnc
and press
ENTER
to confirm and
access the selected menu (menu 4).
If
PWR
is set to OFF, i.e. power output is disabled, move cursor to
PWR
. Press
ENTER
and label will switch to ON, i.e. power output is enabled.
Press
ESC
twice to go back to the default menu (menu 1).
3) Fine tune power setting from menu 2 (see description of item 1b) until achieving
the desired value.
WARNING: Equipment is capable of delivering more than rated output power
(30/50/100/150/300 W for
TEX30/50/100/150/300LCD
respectively); however,
never exceed the specified power rating.
NOTE: If power is set to 0 W in the
Power Setup Menu
, the INTERLOCK OUT
contact is activated and any external appliances connected to it are immediately
inhibited.
Next, you can review all operating parameters of the equipment through the
management firmware.
Normally, the equipment can run unattended. Any alarm condition is handled
automatically by the safety system or is signalled by the LED indicators on the
panel or by display messages.
NOTE: Standard factory settings are output power set to upper limit (unless
otherwise specified by customer) and
OFF
.
5.4 Management Firmware
The equipment features an LCD with two lines by 16 characters that displays a
set of menus. The figure below provides an overview of equipment menus.
The symbols listed below appear in the left portion of the display as appropriate:
(Cursor) - Highlights selected (i.e. accessible) menu.
(Filled arrow) - Editable parameter marker. This symbol appears in menus that
take up more than two lines to aid browsing.
(Three empty arrows) - Parameter is being edited.
(Empty arrow) - Current line marker; the parameter in this line cannot be
edited. This symbol appears in menus that take up more than two lines to aid
browsing.