10
/ 32
User Manual
Rev. 1.0 - 29/11/12
TEX30/50/100/150/300LCD
ELETTRONICA
5. Quick guide for installation and use
This section provides a step-by-step description of equipment installation and
configuration procedure. Follow these procedures closely upon first power-on
and each time any change is made to general configuration, such as when a new
transmission station is added or the equipment is replaced.
Once the desired configuration has been set up, no more settings are required
for normal operation; at each power-up (even after an accidental shutdown),
the equipment defaults to the parameters set during the initial configuration
procedure.
The topics covered in this section are discussed at greater length in the next
sections, with detailed descriptions of all hardware and firmware features and
capabilities. Please see the relevant sections for additional details.
IMPORTANT:
When configuring and testing the transmitter in which the equipment
is integrated, be sure to have the Final Test Table supplied with the equipment ready
at hand throughout the whole procedure; the Final Test Table lists all operating
parameters as set and tested at the factory.
5.1 Prepation
5.1.1 Preliminary checks
Unpack the exciter and immediately inspect it for transport damage. Ensure that
all connectors are in perfect condition.
The main fuse can be accessed from the outside on the rear panel. Extract the
fuse carrier with a screwdriver to check its integrity or for replacement, if necessary.
The fuse to be used is this type:
Fusibile principale
TEX30LCD
@ 90÷260 Vac
(1x) 3.15A tipo 5x20
TEX50/100/150LCD
@ 230 Vac/115 Vac
(1x) 6.3A tipo 5x20
TEX300LCD
@ 230 Vac/115 Vac
(1x) 8A tipo 5x20
Table 5.1:
Fuses
Provide for the following (applicable to operating tests and putting into service):
√
Single-phase 230 VAC or 115 VAC (-15% / +10%) mains power supply for
TEX50/100/150LCD
, or 80÷260 VAC full-range mains power supply for
TEX30/
300LCD
, with adequate earth connection.