R-Tech PLASMA 60HF Скачать руководство пользователя страница 11

 

11

 
When in the up position this is in auto mode, this is for special applications when using 
automated machinery. Not normally used 

 

Operating machine 

 

SAFETY PRECAUTIONS 

 

WARNING! 

 

 
ELECTRIC SHOCK CAN KILL 
 
Do not touch electrically live parts or electrode with skin or wet clothing. 
Insulate yourself from work and ground 
Always wear dry insulating gloves 

 

WARNING! 

 

 
FUMES AND GASES can be dangerous 
 
Keep your head out of fumes & gases produced from welding. 
Use ventilation or exhaust to remove fumes & gases from breathing zone and general 
area.

 

WARNING! 

 

 
WELDING SPARKS can cause fire or explosion 
 
Keep flammable material away from work area. 
Do not weld on containers that have held combustibles 
 

WARNING! 

 

 
ARC RAYS can burn 
 
Wear eye, ear and body protection – Make sure work area is protected by proper shielding 
to avoid injury to passers by. 
 
 
 
 
 
 
 

Содержание PLASMA 60HF

Страница 1: ...www r techwelding co uk Email sales r techwelding co uk Tel 01452 733933 Fax 01452 733939 PLASMA 60HF INVERTER PLASMA CUTTER OPERATION INSTRUCTIONS...

Страница 2: ...2...

Страница 3: ...for future reference This information can be found on data plate at rear of machine Product Plasma 60HF Serial No ___________________________________ Date of Purchase _____________________________ Wh...

Страница 4: ...ts output capacity of 60 Amps DC Equipment Limitations The R Tech Plasma 60HF is protected from overloads beyond the output ratings and duty cycle as per machine specifications with thermostat protect...

Страница 5: ...cessive operating temperatures which can lead to plant failure Grinding Do not direct grinding particles towards the plasma cutter An abundance of conductive material can cause plant failure Stacking...

Страница 6: ...ng equipment as per following instructions should minimize problems 1 Keep the welder input power lines as short as possible and enclose as much of them as possible in metal conduit or equivalent shie...

Страница 7: ...sma Cutters require a 415V 3 Phase 50 60Hz supply It requires an 12 5 Amp supply It comes with a 3 metre mains cable attached Connect wires according to national coding Brown wire Live Blue wire Live...

Страница 8: ...and turn to adjust pressure once correct pressure is obtained press down knob to secure 2 Air pressure input Screw supplied PCL fitting into regulator ensuring no air leaks You can also fit other conn...

Страница 9: ...nsert male connector into socket and twist clockwise until tight Secure other end of earth lead to Workpiece via the earth clamp 2 Fuse holder Pilot Arc Protection Protection fuse for pilot arc start...

Страница 10: ...hen you are cutting 3 L E D amperage display When cutting this shows the actual cutting amperage this allows the machine to be calibrated to BS if required by your company 4 Test Gas Cutting selector...

Страница 11: ...nd Always wear dry insulating gloves WARNING FUMES AND GASES can be dangerous Keep your head out of fumes gases produced from welding Use ventilation or exhaust to remove fumes gases from breathing zo...

Страница 12: ...lue flame from torch once the pilot arc is in contact with the workpiece it will sense this and switch to main cutting power Once you come to the end of cut workpiece the machine will sense this and t...

Страница 13: ...e 1 Switch off machine 2 Ensure torch has cooled down to avoid burns 3 Unscrew the pink ceramic shroud 4 Remove the silver cutting tip 5 Check the condition of cutting electrode replace cutting electr...

Страница 14: ...working inside this equipment Do not touch electrically live parts 1 Periodically 3 6 months depending on use environment remove the side top panels of machine and clean out machine with a low pressur...

Страница 15: ...orch consumables and replace if worn Check pilot arc protecting fuse on front panel of machine and replace if blow If fuse keeps blowing contact R Tech for repair replacement torch Please ensure machi...

Страница 16: ...n air compressor clean water out of air lines empty water trap by pressing water release button on bottom of air regulator water trap Fit new consumables as per instructions earlier in this manual Pla...

Страница 17: ...17 Plasma torch switch TS1 Wiring Diagram...

Страница 18: ...18...

Страница 19: ...19...

Отзывы: