Replacing torch consumables
WARNING!
ELECTRIC SHOCK CAN KILL
Please ensure machine is turned off before changing consumables
If cutting performance is poor you probably need to check / change the torch consumables. To change the plasma
cutting consumables carry out the following procedure
1. Switch off machine
2. Ensure torch has cooled down to avoid burns
3. Unscrew the retaining nozzle
4. Remove the cutting tip
5. Check the condition of cutting electrode, replace cutting electrode if tip is worn 1-2 mm and end is concave
6. Fit new cutting tip if required if cutting hole is distorted or an angled cut happens replace the cutting tip
7. It is normally good practice to replace electrode and cutting tip as a pair
8. Check condition of brown baker lite swirl ring, if signs of pitting / burning replace item
9. Refit retaining nozzle by screwing on hand tight
10. Turn machine back on and continue cutting