- 12 -
XR-OP-EN
MACHINE SETUP
UN-CRATING MACHINE:
Carefully check the crate for any signs of damage and that
the batteries are in the unit.
To un-crate the machine, remove banding strips from
around the crate. Take off the top and sides and dispose
properly. Remove brackets from machine wheels.
Remove bolts from pallet, then remove board. Carefully
roll the machine off of the base. Notify the carrier
immediately if concealed damage is discovered.
CONNECTING BATTERIES:
Your machine is equipped with (6
×
) 6-Volt/ 325 AH, (6
×
)
6-Volt/ 400 AH, (6
×
) 6-Volt/ 420 AH, or (1
×
) 36-Volt/
440 AH Wet Lead Acid, AGM, Industrial, or Deep Cycle
Batteries which form a 36 Volt system.
(SEE PICTURE BELOW OR BATTERY DISCONNECT
LABEL FOR CORRECT CABLE CONNECTIONS)
1. Turn all switches to the
OFF
position and remove Key.
2. Tip Tank back. Attach all Battery Cables to Terminals
as shown below.
3. Turn
ON
main power switch and check the LCD
to ensure correct installation. Charge Batteries if
needed
(SEE BATTERY CHARGING)
.
NOTICE
Batteries are a possible environmental hazard. Consult
your Battery supplier for safe disposal methods.
NOTICE
Orientation of Batteries is critical for cables to reach.
ATTACHING SQUEEGEE:
1. Lower the Squeegee Mounting Plate by depressing the
Squeegee Lift switch
(A)
(SEE BELOW)
.
2. Loosen the two knobs
(B)
on the Squeegee and slide
them into the slots in the Squeegee Mounting Plate
(SEE BELOW)
.
3. Tighten the two knobs and connect the Vacuum Hose
(C)
from the machine to the Squeegee
(SEE BELOW)
.
4. You may have to adjust the Squeegee Pitch
(SEE
ADJUSTING SQUEEGEE ON THE NEXT PAGE)
6V
6V
6V
6V
6V
6V
MONO-BLOCK
36 VOLTS
36 VOLTS
A
C
B
B