Use “?” to list available commands as shown below.

>?

YOUNG 61302L SERIES BAROMETER V2.02

----------------------------------------

CMD100 n   OUTPUT PERIOD (0-60 sec)

CMD105 n   AVG SAMPLE COUNT (0-32)

CMD110 n   OUTPUT FORMAT

 

(1=ASCII 2=POLLED 3=NMEA 4-RAW 5-DIAG)

CMD120 n   MULTIPLIER (10000 = 1.0000)

CMD125 n   OFFSET (hPA x 100)

CMD130 n   SEA LEVEL CORRECTION (hPA x 100)

CMD140 n   IOUT RANGE HI (500-1100)

CMD142 n   IOUT RANGE LO (500-1100)

CMD150 c   POLL ADDR CHAR

CMD160 n   BAUD RATE (38400,9600,4800,2400,1200)

CMD300 n   1=STOP, 2=RUN

CMD310 n   FORCE IOUT (0-20000 FULL SCALE)

CMD400 n   1=RPT TEXT, 2=RPT CODE ONLY

CMD410     GET CAL TABLE

CMD420     STORE SETUP PARAMETERS

>

CMD100 n

 sets output period in seconds. When set to 

zero, the output rate is 1.8 per second.

CMD105 n

 sets the average sample count. Higher sample 

count yields more stable readings but will lengthen 

the startup delay.

CMD110 n

 sets output format.

CMD120 n

 sets the output multiplier. 10000 represents 

1.0000                    

CMD125 n

 sets the output offset in hPa x 100

CMD130 n

 sets the sea level correction in hPa x 100

 

=[

P

unadjust

 

*(

 Mult / 10000

)]

 

+

 

[(

Offset 

/

100

)

 

+

 

(

Correction

 

Sea Lvl

 

/

 100

)]

 

CMD140 n 

sets the IOUT Pressure Range HI

CMD142 n 

sets the IOUT Pressure Range LO

 

IOUT Pressure Range HI must be greater than IOUT 

Pressure Range LO

CMD150 c 

sets the poll address character. Any ASCII 

character from ‘0’ (ASCII 48) to ‘z’ (ASCII 122) may 

be used.

CMD160 n 

sets the baud rate. Acceptable values are 

38400, 9600, 4800, 2400, and 1200. Note that the 

baud rate change occurs immediately after the 

command is received. Therefore, in order to continue 

communicating, the serial communication program 

that issued the command must also change to 

match.

CMD300 n 

causes the sensor to pause or resume 

measurement. 1 = Stop, 2 = Run.

CMD400 n 

causes the sensor to issue a report 

summarizing parameter settings.

 

1 = Text (parameter values and labels)

 

2 = Code Only (parameter values only).

CMD420 

burns the current parameter settings to flash 

memory. This step 

must

 take place to retain 

changes to settings otherwise parameters will revert 

to previous values at the next power up.

5.0 MAINTENANCE

The  MODEL  61302L  barometer  requires  no  regular 

maintenance.  Periodic calibration certification, if required, 

is available from the factory.

6.0 WARRANTY

This product is warranted to be free of defects in materials 

and construction for a period of 12 months from date of 

initial purchase. Liability is limited to repair or replacement 

of defective item. A copy of the warranty policy may be 

obtained from R. M. Young Company.

7.0 EMC COMPLIANCE

This device complies with Part 15 of the FCC Rules. Operation 

is  subject  to  the  following  two  conditions:  (1)  this  device  may 

not cause harmful interference, and (2) this device must accept 

any interference received, including interference that may cause 

undesired operation.

This equipment has been tested and found to comply with the 

limits  for  a  Class A  digital  device,  pursuant  to  part  15  of  the 

FCC  Rules.  These  limits  are  designed  to  provide  reasonable 

protection  against  harmful  interference  when  the  equipment 

is  operated  in  a  commercial  environment.  This  equipment 

generates, uses, and can radiate radio frequency energy and, if 

not installed and used in accordance with the instruction manual, 

may  cause  harmful  interference  to  radio  communications.  

Operation  of  this  equipment  in  a  residential  area  is  likely  to 

cause  harmful  interference  in  which  case  the  user  will  be 

required to correct the interference at his own expense.

This ISM device complies with Canadian ICES-001.

Cet appareil ISM est conforme à Ia norme NMB-001 du Canada.

EN55011/CISPR 11, Group 1, Class B device.

Class B equipment is suitable for use in domestic establishments 

and in establishments directly connected to a low voltage power 

supply  network  which  supplies  buildings  used  for  domestic 

purposes.

8.0 CE COMPLIANCE