Appendix A
Troubleshooting Using the CLI
121
set expander-fault-isolation
When fault isolation is enabled, the Expander Controller will isolate PHYs that fail
to meet certain criteria. When fault isolation is disabled, the errors are noted in the
logs but the PHYs are not isolated.
For details about using
set expander-fault-isolation
, see the
CLI
reference guide
.
set expander-phy
The Expander Controller will enable or disable (isolate) the specified PHY.
For details about using
set expander-phy
, see the
CLI reference guide.
set led
Changes the state of drive module or enclosure LEDs to help you locate devices.
For a drive module, the Power/Activity/Fault LED will blink yellow. For an
enclosure, the Unit Locator LED on the chassis ear and on each controller module
will blink white.
For details about using
set led
, see the
CLI reference guide
.
set protocols
Enables or disables one or more of the following service and security protocols.
■
http
, for standard access to RAIDar
■
https
, for secure access to RAIDar
■
telnet
, for standard access to the CLI
■
ssh
, for secure access to the CLI
■
ftp
, an alternate interface for firmware upgrade
■
Storage Management Initiative Specification (SMI-S)
■
Simple Network Management Protocol (SNMP)
■
Telnet service port 1023
■
Telnet debug port 4048
■
In-band CAPI management interface
■
In-band SES management interface
For details about using
set protocols
, see the
CLI reference guide.
Содержание 2000 Series
Страница 1: ...2000 Series Troubleshooting Guide P N 83 00004287 12 Revision A May 2008 ...
Страница 18: ...18 R Evolution 2000 Series Troubleshooting Guide May 2008 ...
Страница 34: ...34 R Evolution 2000 Series Troubleshooting Guide May 2008 ...
Страница 64: ...64 R Evolution 2000 Series Troubleshooting Guide May 2008 ...
Страница 78: ...78 R Evolution 2000 Series Troubleshooting Guide May 2008 ...