Chapter 6
Voltage and Temperature Warnings
75
the fan speed remains under the 4000 RPM threshold, the internal enclosure
temperature may continue to rise. Replace the power-and-cooling module reporting
the fault.
During a shutdown, the cooling fans do not shut off. This allows the enclosure to
continue cooling.
Temperature Sensors
Extreme high and low temperatures can cause significant damage if they go
unnoticed. Each controller module has six temperature sensors. Of these, if the CPU
or FPGA temperature reaches a shutdown value, the controller module is
automatically shut down. Each power-and-cooling module has one temperature
sensor.
When a temperature fault is reported, it must be remedied as quickly as possible to
avoid system damage. This can be done by warming or cooling the installation
location.
Table 6-2
Cooling Fan Sensor Descriptions
Description
Location
Event/Fault ID
LED Condition
Fan 0
Power-and-cooling module 0
< 4000 RPM
Fan 1
Power-and-cooling module 0
< 4000 RPM
Fan 2
Power-and-cooling module 1
< 4000 RPM
Fan 3
Power-and-cooling module 1
< 4000 RPM
Table 6-3
Controller Module Temperature Sensors
Description
Normal
Operating
Range
Warning
Operating
Range
Critical
Operating
Range
Shutdown
Values
CPU Temperature
3–88
°
C
0–3
°
C,
88–90
°
C
> 90
°
C
0
°
C
100
°
C
FPGA Temperature
3–97
°
C
0–3
°
C,
97–100
°
C
None
0
°
C
100
°
C
Onboard Temperature 1
0–70
°
C
None
None
None
Onboard Temperature 2
0–70
°
C
None
None
None
Содержание 2000 Series
Страница 1: ...2000 Series Troubleshooting Guide P N 83 00004287 12 Revision A May 2008 ...
Страница 18: ...18 R Evolution 2000 Series Troubleshooting Guide May 2008 ...
Страница 34: ...34 R Evolution 2000 Series Troubleshooting Guide May 2008 ...
Страница 64: ...64 R Evolution 2000 Series Troubleshooting Guide May 2008 ...
Страница 78: ...78 R Evolution 2000 Series Troubleshooting Guide May 2008 ...