Bubble
‐
Up®
Jr
Interactive™
Radon
Removal
System
12
Start
Up
Procedure
1.
Set
the
red
handles
on
the
bypass
valve
to
the
Service
position.
2.
Before
plugging
in
Bubble
‐
Up®
Jr
Interactive™,
identify
the
plug
‐
in
cords.
See
figure
8.
3.
Plug
in
the
meter
control
and
water
alarm
valve
control
power
cords.
4.
Push
reset
button
on
water
alarm
valve
control
for
3
seconds
to
open
the
motorized
ball
valve.
5.
Plug
in
the
yellow
cord
first.
The
blower
should
start,
and
the
solenoid
valve
should
open
to
begin
filling
the
tank.
6.
As
the
water
level
in
the
tank
rises,
the
fill
float
switch
will
tilt
up.
This
will
stop
the
blower
and
close
the
solenoid
valve.
7.
Once
the
tank
is
full,
plug
in
the
black
pump
control
cord.
8.
If
the
pump
does
not
start
delivering
water
to
the
house,
it
may
be
necessary
to
prime
the
pump.
(Normally
you
will
only
have
to
do
this
once,
when
the
unit
is
first
installed.)
The
pump
is
suspended
by
a
pipe
underneath
the
pump
control.
Unscrew
the
union
and
move
the
pump
control
off
to
the
side.
You
may
need
to
siphon
or
vacuum
the
water
up
this
pipe
to
remove
the
air
from
the
pump
and
prime
it.
9.
Once
the
air
has
been
removed
from
the
pump,
replace
the
pump
control
and
tighten
the
union.
Plug
in
the
pump.
If
the
pump
does
not
start
delivering
water
to
the
house,
repeat
the
priming
sequence.
10.
After
the
unit
is
operating,
run
a
radon
test
of
the
raw
water
and
the
filtered
water
to
ensure
that
the
unit
is
reducing
radon
levels
in
the
water.
Radon
Testing
Note:
It
is
important
to
install
a
new
sample
valve
or
boiler
drain
in
new
piping
so
that
the
radon
testing
is
not
influenced
by
old
piping.
11.
Perform
the
six
‐
month
maintenance
procedure,
and
fill
out
the
Start
‐
Up
Data
page
at
the
end
of
this
manual.
Operating
Instructions
Once
the
Bubble
‐
Up®
Jr
Interactive™
has
been
installed,
it
should
operate
with
very
little
attention.
Normal
Operation
Main
Unit
The
unit
should
not
need
any
operator
attention.
When
water
is
used
in
the
house,
the
2.1
gallon
water
expansion
tank
delivers
water
demand.
When
the
pressure
drops
to
the
set
pressure,
the
mechanical
pump
control
starts
the
Bubble
‐
Up®
Jr
Interactive™
pump
to
deliver
water
to
the
home
and
refill
the
2.1
gallon
water
expansion
tank.
When
the
mechanical
pump
control
senses
normal
household
pressure,
the
mechanical
pump
control
shuts
the
Bubble
‐
Up®
Jr
Interactive™
pump
off.
As
the
water
level
falls
in
the
Bubble
‐
Up®
Jr
Interactive™
main
tank,
the
float
switch
powers
the
blower
and
solenoid
to
fill
the
Bubble
‐
Up®
Jr
Interactive™
tank
with
treated
water.
Low
Water
Cut
‐
Out
Float
Switch
The
pump
will
automatically
stop
when
there
is
low
water
in
the
Bubble
‐
Up
tank.
The
pump
will
automatically
restart
when
water
is
replenished.
Water
Alarm
Valve
The
water
alarm
valve
is
in
place
for
protection
against
leaking
or
overflowing
and
will
not
operate
unless
one
of
these
things
happens.
Once
the
water
alarm
valve
control,
overflow
alarm
float,
floor
sensor
or
terminal
block
senses
a
problem
in
the
system
the
water
alarm
valve
control
activates
the
motorized
ball
valve
and
shuts
off
the
incoming
water.
The
water
alarm
valve
control
will
also
sound
an
alarm
to
identify
that
there
is
a
problem.