Bubble
‐
Up®
Jr
Interactive™
Radon
Removal
System
26
TECHNICAL
DATA
Flow
Rate…………………………………...See
Pressure
flow
chart
below
Power
source………………………….
115
Volt
AC,
60
Hz,
single
phase
HP
rating
…………………………………………..………………1.5
HP
115
volt
Operating
Pressure
Range………………………………………….
0
–
75
PSI
Maximum
Allowable
Pressure………………………………………...
80
PSI
Maximum
Liquid
Temperature…………………………………………
100°F
Connection…………………….
1”
SCD
80
union
inlet,
1/2”
PEX
outlet
Protection
Level…….………………UL
Listed
Pressure
Switch
&
cords
C.
INSTALLATION
1.
Use
only
115
volt
outlet
for
the
Bubble
‐
Up
mechanical
pump
control.
2.
The
bottom
1”
schedule
80
union
and
top
½”
PEX
fittings
are
to
be
water
tight
and
secure.
3.
Check
that
the
pump
is
primed
before
plugging
in
the
Bubble
‐
Up
mechanical
pump
control.
4.
The
Bubble
‐
Up
mechanical
pump
control
is
supplied
with
115
volt
electrical
cords.
Connect
the
pump’s
male
power
plug
into
the
Bubble
‐
Up
mechanical
pump
control
female
cord.
5.
To
start
the
pump,
refer
to
OPERATION
below.
6.
The
pressure
switch
factory
set
at
to
turn
the
pump
on
at
45
PSI.
To
set
pressure
switch
for
proper
operation
see
instructions
above.
WARNING!
Unplug
the
Bubble
‐
Up
mechanical
pump
control
before
removing
the
pressure
switch
cover.
7.
Always
use
the
bladder
tank
provided
with
the
Bubble
Up.
The
correct
pre
‐
charge
air
pressure
in
the
tank
is
40
psi.
D.
OPERATION
See
setting
pressure
switch
above.
The
Bubble
‐
Up
mechanical
pump
control
starts
the
pump
when
the
pressure
drops
to
45
PSI.
The
pump
will
run
constant
when
the
flow
is
greater
than
½
to
1
GPM.
When
water
flow
falls
below
½
to
1
GPM,
water
fills
the
required
cycle
tank
providing
a
minimum
run
time
before
the
pump
is
shut
off.
Internal
parts
include:
2
‐
Check
Valves,
a
Nozzle
and
Throat
Assembly
with
retainer,
Double
Check
Valve
and
Nozzle
Retainer
and
3
screws.