background image

Fig. 5

Fig. 6

WARNING – 

Turn off the power.

1. Remove the two fan base screws that 
pre-installed on the top of the wall 
mounting plate, keep it for future use.

2. Install the wall mounting plate to the 
wall junction box and secure with six 
screws provided. (Figure 2)

3. Remove the three wire nuts from the 
bundled wires. (Figure 3)

4. Attached the bundled wires to the 
building supply wires out of the wall 
junction box with wire nuts removed 
previously. (Figure 3)
     Black to black

      

White to white

      

Blue to blue

5. Detach the wireway passage plate from 
the fan base by removing two screws 
from the fan base. (Figure 4) The plate 
covers a temporary wireway passage for 
making the wiring connection. 

6. Hanging the fan motor assembly to the 
wall mounting plate, ensure the two 
hanging bars sliding into the notch of 
hook completely. (Figure 5)

NOTE: 

Make sure the two wire 

connectors are revealed through the 
wireway passage after hanging the fan 
motor assembly onto the wall mounting 
plate. 

7. Make the connection for the two wire 
connectors, and then tuck the wires inside 
the fan base. (Figure 5)

8. Re-install the fan base screws that 
removed previously into the fan base. 
(Figure 6)

9. Re-attach the wireway passage plate 
onto the fan base and secure with screws 
removed previously. (Figure 6)

10. Your wall fan is now completed the 
wall mounted installation.

4. MOUNTING/INSTALLATION 
    OF THE FAN

Fig. 2

Fig. 3

Fig. 4

Screws

Fan base

Screws

Fan base screws

Wire nuts

Bundled 
wires 

To wall control

Wall mounting
plate

Wall mounting
plate screws

Fan base screws

To wall control

Hook

Hanging 
bars

Wire 
connectors

To wall control

Wireway
passage
plate

Wireway
passage
plate

Содержание The Veranda

Страница 1: ...read and save these instructions These instructions are to be used in the installation of the following QUORUM INTERNATIONAL fans The Veranda P O Box 961008 Fort Worth TX 76161 817 626 5483 FAX 817 626 5540 IO220 01 14 2014 Quorum International All Rights Reserved ...

Страница 2: ...estions regarding the warranty or the procedures for obtaining service please call us at 817 626 5483 Monday thru Friday 8 00 a m 5 00 p m CST technical skill competence or experience of the user 8 Light bulbs glass or acrylic components or accessories 9 Minor occurrences of wobble are accepted as normal and should not necessarily be considered a defect WHO MAY ENFORCE WARRANTY This warranty may b...

Страница 3: ... the National Electrical Code If you are unfamiliar with electric wiring please use a qualified and licensed electrician 4 When cutting or drilling into wall or ceiling do not damage electrical wiring and other hidden utilities 5 Before applying power visually re inspect the installation Make sure that all guards and protective devices are securely in place and all visible screws and bolts are tig...

Страница 4: ...l junction box or make sure the existing box is secured directly to the building structure Use appropriate fasteners and building materials CAUTION TO REDUCE THE RISK OF PERSONAL INJURY INSTALL THE PRIMARY MOUNTING MEANS AND USE ONLY THE HARDWARE PROVIDED WITH THE FAN 3 MOUNTING OPTIONS WARNING TO REDUCE THE RISK OF ELECTRIC SHOCK FIRE OR PERSONAL INJURY MOUNT THE FAN ONLY TO AN OUTLET MARKED ACCE...

Страница 5: ...he wall mounting plate ensure the two hanging bars sliding into the notch of hook completely Figure 5 NOTE Make sure the two wire connectors are revealed through the wireway passage after hanging the fan motor assembly onto the wall mounting plate 7 Make the connection for the two wire connectors and then tuck the wires inside the fan base Figure 5 8 Re install the fan base screws that removed pre...

Страница 6: ...unit Remove the existing wall plate and switch from the wall junction box Connect blue wire labeled FOR OSCILLATION from wall control to blue or red wire from wall junction box Connect black wire labeled TO MOTOR L from wall control to black wire from wall junction box Connect the black white wire labeled AC IN L from the wall control to the black wire from A C supply source If your wall junction ...

Страница 7: ...hould see a significant reduction in your cooling costs by regular use of your fan 2 A clicking or a rattling noise is a sure indication of loosening screws Since screws will invariably work loose over time at least once a year tighten all the screws for this fan 3 Clean you fan periodically using only a cloth dampened with a mild detergent solution for all hardware never use solvents The finish p...

Страница 8: ... cage motor etc 1 Check to see that all screws are tight in the fan cage connection to the motor face plate 2 Turn off the power Loosen the fan base and check that the wiring and or wire nut connectors are not resting against the fan base possibly vibrating while the fan is on 3 Use of a standard light rheostat or an unapproved fan wall control to control the fan speed will always cause an annoyin...

Отзывы: