1.2 General safety precautions 

To  avoid  personal  injury  and/or  property  damage,  the  following  safety  precautions  must  be  followed. 
Damage caused by improper handling or failure to follow these precautions are not subject to warranty. No 
liability for resulting damages is assumed by QUORiON! 
 

 

Warning! 
Electric shock and fire hazards due to improper commissioning and handling 

Risk of severe burns or death 

–  Only use the device with the corresponding supplied AC adapter. Do not connect 

power adapters from other manufacturers. 

–  Never use a damaged power cable. 
–  Make sure your power cable meets the relevant safety standards and includes a 

power-system ground terminal (PE terminal). 

–  Before connecting the device make sure that the voltage of your main power net 

corresponds to the input voltage printed on the rating plate of your device. 

–  Never connect or disconnect the power plug with wet hands. 
–  Always connect the power cable to the device before connecting it to the wall outlet. 
–  Only connect the device to a socket with a grounded protective conductor. 
–  Only use original QUORiON components or components and peripherals approved by 

QUORiON. 

–  Opening the device as well as maintenance and repair work has to be carried out by 

qualified service technicians only. 

–  Do not make any modifications to the device and its components and peripherals. 
–  Keep away any liquids from the device and do not place any containers with liquids on 

the device. Disconnect the device from the main power net before cleaning. If any 
liquid spills into the equipment, unplug the power cable immediately and contact your 
local dealer for advice. 

 

 

Caution! 
Equipment damage due to improper commissioning and handling 

Internal and external damage to the POS System 

–  Place the device on a firm, stable, horizontal surface. 
–  Switch off the device before connecting or disconnecting any peripheral devices. 
–  Use only shielded cables for connecting any peripheral devices. 
–  Cables should be routed in a manner that no one can step on or trip over. 
–  Never attempt to stretch the cables to enable a connection. The power cable must 

have adequate slack at all times during use. 

–  When disconnecting the power cable hold it firmly at the connector area. Do not tug 

on the cable itself. 

 
 
 
 
 

Содержание QMP 50 Series

Страница 1: ...User Manual Electronic Cash Register QMP 50 series...

Страница 2: ...sfaction The QUORiON QMP 50 series is fully customizable and yet simple to operate Users can easily adapt it to any type of retail and scanning system Moreover our dynamic software generates a compati...

Страница 3: ...14 5 Sign in and Register 16 5 1 Sign in a Clerk Sales Person 16 5 2 Register a Department 16 5 3 Register Pre Programmed PLUs 16 5 4 Multiplication Division 16 5 5 Tendering in Local Currency 17 5 6...

Страница 4: ...4 10 Instructions for maintenance 21 10 1 Cleaning 21 11 Information on the Electromagnetic Compatibility and Safety 22...

Страница 5: ...rce of the danger the consequences of ignoring and the avoiding Caution Caution Indicates a possible danger that may result in minor personal injury or property damage if not avoided The note is marke...

Страница 6: ...with a grounded protective conductor Only use original QUORiON components or components and peripherals approved by QUORiON Opening the device as well as maintenance and repair work has to be carried...

Страница 7: ...pening the device as well as maintenance and repair work has to be carried out by qualified service technicians only Do not make any modifications to the device and its peripherals and components Keep...

Страница 8: ...8 2 2 The cash register and its components Keyboard 36 keys Printer ON OFF Key Operator display Customer Display Interfaces...

Страница 9: ...Printer Internal 58 mm thermal without cutter 38 mm thermal without cutter Interfaces Serial 2 x RS232 5V RJ45 Cash Drawer 1 x RJ11 9V USB 1 x USB 2 0 Device Type B Software Application Application so...

Страница 10: ...PC communication It is not to be used with USB devices like memory sticks scanners printers etc Important Use only shielded cables for connecting any peripheral devices Switch off the cash register b...

Страница 11: ...ear next to the interfaces Now connect the power supply with the power circuit and turn on the QMP 50 series with the main switch The cash register will now load the operating system and automatically...

Страница 12: ...the Easyload lever and fold the Easyloadcover up 3 Remove the paper roll 4 Close the printer cover Note Do not pull out the remaining paper in the opposite direction of the paper feed 3 3 Switch ON OF...

Страница 13: ...n is not always displayed within the user interface of your POS system but can nevertheless been used Individually programmed key within the user interface keyboard layout for example one of the vario...

Страница 14: ...GR Manager all sales operations and registrations all functions with manager authority easy programming P P Programming programming of all functions 4 3 Names of Keys and their Function Key label Key...

Страница 15: ...used to deduct fixed amounts from the total No Sale prints a reference number opens the cash drawer Sub Total calculates sub total prints out receipt copy if no receipt opened Cash Payment used to ten...

Страница 16: ...til a clerk signs in again Sign in a clerk via keyboard 5 2 Register a Department Department keys may be used either to enter free prices or to select PLUs from a list Register 2 00 EUR in department...

Страница 17: ...a table invoice the endorsement message will be added automatically 5 7 No Sale Open Drawer The key No sale allows you to open the cash drawer without registering a sale 6 Corrections 6 1 Clearing of...

Страница 18: ...from department 1 Please note that only those amounts can be voided which were previously entered 6 4 Refund A refund is used to return previously sold items Refund of PLU 1 and 2 Exchange of PLU 1 an...

Страница 19: ...that no percentages are calculated but rather total amounts such as coupons are subtracted added Discount a pre programmed COUPON amount from the total 7 3 Received on Account Paid Out Cash can be pai...

Страница 20: ...or Z Both types contain the same information The X report can be printed as a temporary report at any time because the report data will not be cleared The Z report is a final report after printing th...

Страница 21: ...8 00 only in P 9 2 Adjusting the screen contrast You can change the screen contract directly on your cash register while operating in programming mode by entering 9999 via the cash registers keyboard...

Страница 22: ...unity s 2004 108 EC EMC directive The cash register is a class A device and fulfils the following technical European requirements EN 55022 Norm values and measuring procedures for radio interference p...

Отзывы: