11 Information on the Electromagnetic Compatibility and Safety

 

CE Conformance 

 

 

Important: 

The machine itself is to be operated only with the components supplied by QUORiON. 
Only use and connect original peripheral devices or peripheral devices approved by 
QUORiON. 

 

 

Important: 

If the cash register is installed in a system with other devices and components, the system 
including the cash register and all other devices and components have to show EMC 
compliance to the norm. The system integrator is responsible for compliance with the 
EMC 2004/108 directive as well as EC and national laws for installed systems, system 
devices and system components that have not been supplied or tested and approved by 
QUORiON as the manufacturer. 

 
This QUORiON cash register conforms to the European Community’s 2004/108/EC EMC-directive. The cash 
register is a class A device and fulfils the following technical European requirements:  

EN 55022 

„Norm values and measuring procedures for radio interference properties –  characteristics of information 

technology devices“ 

EN 55024 

„Norm values and measuring procedures for the interference  resistance properties– characteristics of 

information technology devices“ 

EN 60950 

„Security measurements for the installation of IT“ 

 

A  "conformance  explanation"  in  compliance  with  the  directives  and  standards  cited  on  top  has  been 
delivered and can be reviewed with the QUORiON Data Systems GmbH. 

 

QUORiON Data Systems GmbH, An der Klinge 6, 99095 Erfurt, Germany (E-mail: [email protected]; web: www.quorion.de)

 

 
 
 
 
 
 
 

Publishing Information 

 

QUORiON Data Systems GmbH 
An der Klinge 6 
99095 Erfurt, Germany 

 

President: Frank Grueschow 
Inc. Reg./Handelsregister: HRB 110880 - Amtsgericht Jena - EAR-NR: WEEE-Register Nr.86659901 

 
 

 

1.50.417389 UM-English QMP 50 series QUORION CE (Stand:  20.05.14) 

Содержание QMP 50 Series

Страница 1: ...User Manual Electronic Cash Register QMP 50 series...

Страница 2: ...sfaction The QUORiON QMP 50 series is fully customizable and yet simple to operate Users can easily adapt it to any type of retail and scanning system Moreover our dynamic software generates a compati...

Страница 3: ...14 5 Sign in and Register 16 5 1 Sign in a Clerk Sales Person 16 5 2 Register a Department 16 5 3 Register Pre Programmed PLUs 16 5 4 Multiplication Division 16 5 5 Tendering in Local Currency 17 5 6...

Страница 4: ...4 10 Instructions for maintenance 21 10 1 Cleaning 21 11 Information on the Electromagnetic Compatibility and Safety 22...

Страница 5: ...rce of the danger the consequences of ignoring and the avoiding Caution Caution Indicates a possible danger that may result in minor personal injury or property damage if not avoided The note is marke...

Страница 6: ...with a grounded protective conductor Only use original QUORiON components or components and peripherals approved by QUORiON Opening the device as well as maintenance and repair work has to be carried...

Страница 7: ...pening the device as well as maintenance and repair work has to be carried out by qualified service technicians only Do not make any modifications to the device and its peripherals and components Keep...

Страница 8: ...8 2 2 The cash register and its components Keyboard 36 keys Printer ON OFF Key Operator display Customer Display Interfaces...

Страница 9: ...Printer Internal 58 mm thermal without cutter 38 mm thermal without cutter Interfaces Serial 2 x RS232 5V RJ45 Cash Drawer 1 x RJ11 9V USB 1 x USB 2 0 Device Type B Software Application Application so...

Страница 10: ...PC communication It is not to be used with USB devices like memory sticks scanners printers etc Important Use only shielded cables for connecting any peripheral devices Switch off the cash register b...

Страница 11: ...ear next to the interfaces Now connect the power supply with the power circuit and turn on the QMP 50 series with the main switch The cash register will now load the operating system and automatically...

Страница 12: ...the Easyload lever and fold the Easyloadcover up 3 Remove the paper roll 4 Close the printer cover Note Do not pull out the remaining paper in the opposite direction of the paper feed 3 3 Switch ON OF...

Страница 13: ...n is not always displayed within the user interface of your POS system but can nevertheless been used Individually programmed key within the user interface keyboard layout for example one of the vario...

Страница 14: ...GR Manager all sales operations and registrations all functions with manager authority easy programming P P Programming programming of all functions 4 3 Names of Keys and their Function Key label Key...

Страница 15: ...used to deduct fixed amounts from the total No Sale prints a reference number opens the cash drawer Sub Total calculates sub total prints out receipt copy if no receipt opened Cash Payment used to ten...

Страница 16: ...til a clerk signs in again Sign in a clerk via keyboard 5 2 Register a Department Department keys may be used either to enter free prices or to select PLUs from a list Register 2 00 EUR in department...

Страница 17: ...a table invoice the endorsement message will be added automatically 5 7 No Sale Open Drawer The key No sale allows you to open the cash drawer without registering a sale 6 Corrections 6 1 Clearing of...

Страница 18: ...from department 1 Please note that only those amounts can be voided which were previously entered 6 4 Refund A refund is used to return previously sold items Refund of PLU 1 and 2 Exchange of PLU 1 an...

Страница 19: ...that no percentages are calculated but rather total amounts such as coupons are subtracted added Discount a pre programmed COUPON amount from the total 7 3 Received on Account Paid Out Cash can be pai...

Страница 20: ...or Z Both types contain the same information The X report can be printed as a temporary report at any time because the report data will not be cleared The Z report is a final report after printing th...

Страница 21: ...8 00 only in P 9 2 Adjusting the screen contrast You can change the screen contract directly on your cash register while operating in programming mode by entering 9999 via the cash registers keyboard...

Страница 22: ...unity s 2004 108 EC EMC directive The cash register is a class A device and fulfils the following technical European requirements EN 55022 Norm values and measuring procedures for radio interference p...

Отзывы: