background image

Disconnecting tank

• In case of service.
• The Q-shaped button on top of the tank is the on/off switch.

1 Switching off

Press the on/off switch at the top of

the tank to switch it off. Do not

unplug the tank from the socket yet.

2 Draining

Open the boiling-water tap or the

boiling-water handle of the Fusion tap

and leave the water running until it is

cold. Then close the tap again.

3 Isolating

Close the main shut-off valve or the

stop valve on the inlet combination

(small grey knob). Check that the

Quooker is depressurized by opening

the Nordic boiling-water tap or the

boiling-water handle of the Fusion tap

again. If it is depressurized, no water

should flow out of it.

4 Disconnecting

Unplug the tank from the socket and

the LED cable from the back of the

tank cover. Disconnect the tap and

inlet hoses and remove the tank. Drain

the tank into the sink via the hoses.

F

1

2

3

4

Содержание Combi E

Страница 1: ...Installation guide COMBI E Before installing read this guide first...

Страница 2: ...ature the Nordic boiling water tap is height adustable and both the Nordic boiling water tap and the Fusion tap are fully insulated Despite all the safety features incorporated in the product anyone u...

Страница 3: ...for use by visitors at hotels motels bed breakfasts and other residential accom modation Always follow the installation method described in the manual Avoid spilling water on the plug If defective th...

Страница 4: ...romagnetic Compatibility Directive 2014 68 EU Pressure Equipment Directive And are in conformity with the following standards EN60335 1 2012 A11 2014 EN60335 2 15 2002 A1 2005 A2 2008 A11 2012 EN62233...

Страница 5: ...unting bracket optional yes Safety features maximum temperature fuse pressure relief valve 800 kPa 8 bar HiTAC water filter High Temperature Activated Carbon These are average values Energy label Decl...

Страница 6: ...ss fixing plate fixing nut white tap support for thin work tops and two inlet hose screens 3 Quooker inlet combination waste hose Quooker drill bit PVC connector and large fibre washers 4 Mixing valve...

Страница 7: ...ling water tap C Connecting water D Connecting waste E Connecting tank Note Bear in mind that the tank inlet combination mixing valve and socket must remain accessible for servicing For an overview of...

Страница 8: ...er A Drilling hole B2 Fitting boiling water tap C Connecting water D Connecting waste E2 Connecting tank with Fusion tap Note Bear in mind that the tank inlet combination mixing valve and socket must...

Страница 9: ...Nordic boiling water tap has a reach of 16 cm from the centre of the tap hole keep this in mind when choosing the tap position 1 2 3 A 1 Select position boiling water tap Select a suitable position f...

Страница 10: ...ecuring tap screws Tighten the screws in the screw ring 1 2 Fitting Nordic tap Note The total length of the hose between the boiling water tap and tank is only 70 cm The tank must therefore be fitted...

Страница 11: ...t the position of the tap to ensure that the Quooker logo is facing the user When the handle is in the cold position it will be parallel to the edge of the work top Tighten the fixing nut with a pipe...

Страница 12: ...see figure at step D4 1 Fitting pressure reducing valve Close the main shut off valve Fit the pressure reducing valve to the T joint and subsequently to the cold water pipe 15 mm NOTE The pressure re...

Страница 13: ...ed drill and tap in one operation a threaded hole in the waste pipe Drill slowly so that the PVC does not melt Turn back anti clockwise to preserve the thread 2 Fit connector First try to screw the PV...

Страница 14: ...han the ones supplied 1 2 3 4 1 Connecting tank Place the tank in position and connect the tank hoses to the mixing valve NOTE The hoses have flare fittings and should not be fitted with any seals or...

Страница 15: ...pplied 1 2 3 4 1 Connecting tank Place the tank in position and connect the tank hoses to the mixing valve NOTE The hoses have flare fittings and should not be fitted with any seals or washers Connect...

Страница 16: ...ntil it is cold Then close the tap again 3 Isolating Close the main shut off valve or the stop valve on the inlet combination small grey knob Check that the Quooker is depressurized by opening the Nor...

Страница 17: ...UK 30 226 03 V12 Q U O O K E R U K L T D 3 Waterpark Hall Montpellier Mews Salford M7 4ZY UK P 44 0 207 9233355 F 44 0 207 9001590 E mail info quooker co uk Internet quooker co uk www quooker co uk...

Отзывы: