Section II - Description
Air Flow
When the compressor is operating,
a partial vacuum is produced at the
compressor inlet. Air entering via the air
fi lter fl ows through the inlet valve into
the rotor housing where it is compressed,
then discharged into the air/fl uid reservoir.
Compressed air passes through the air/
fl uid separator, then through a minimum
pressure check valve, through the
aftercooler and moisture trap to the service
connection.
Cooling System
Air-cooled Fluid Coolers
The air-cooled fl uid cooler and aftercooler
are fi nned aluminum plate design. QSI-
90, 120 and 140 models use a one-piece
combination cooler/aftercooler. Ambient
air is induced through the fi ns by a
centrifugal fan, cooling the fl uid and air in
the plates. To maintain proper compressor
operation, the ambient air temperature
should not exceed the temperatures listed
in Appendix B - Technical Data. The cooler
fi ns must be kept clean at all times. Fluid
leaving the receiver passes through a
thermal mixing valve before traveling on
to the cooler. The purpose of the thermal
valve is to maintain a minimum fl uid
discharge temperature at the compressor
of approximately 190°F.
Aftercoolers
Aftercoolers reduce the amount of water
in the discharge air. They are used to
lower the temperature of the discharge
air thereby condensing water vapor from
the compressed air. This allows most of
the contained water to be trapped and
expelled from the unit, reducing water
related problems downstream.
Moisture Separator
A combination moisture separator and
water trap is provided for collecting and
expelling water to the customer’s drain.
5
Содержание QSI-90
Страница 2: ......
Страница 70: ...Appendix A Dimensional Drawings QSI 90 120 140 micro 66...
Страница 71: ...Appendix A Dimensional Drawings QSI 90 120 140 micro dry 67...
Страница 72: ...Appendix A Dimensional Drawings QSI 90 120 140 micro tank mounted 68...
Страница 73: ...Appendix A Dimensional Drawings QSI 90 120 140 micro dry tank mounted 69...
Страница 74: ...Appendix A Dimensional Drawings QSI 90 120 140 guage 70...
Страница 75: ...Appendix A Dimensional Drawings QSI 90 120 140 guage dry 71...
Страница 76: ...Appendix A Dimensional Drawings QSI 90 120 140 guage tank mounted 72...
Страница 77: ...Appendix A Dimensional Drawings QSI 90 120 140 guage dry tank mounted 73...
Страница 78: ...Appendix A Dimensional Drawings QGV 20 25 30 460V 74...
Страница 79: ...Appendix A Dimensional Drawings QGV 20 25 30 460V dry 75...
Страница 80: ...Appendix A Dimensional Drawings QGV 20 25 30 460V tank mounted 76...
Страница 81: ...Appendix A Dimensional Drawings QGV 20 25 30 460V dry tank mounted 77...
Страница 91: ......