Section V - Servicing
Maintenance Schedule
This Schedule is intended to be used as a guideline only. Depending on the specifi c
operating conditions of your QSI compressor, maintenance requirements may vary. The
instructions in this section will give more details about determining when specifi c service
should be performed.
P
ERIODICALLY
/D
AILY
(8
HOURS
MAXIMUM
):
M
ONITOR
ALL
GAUGES
AND
INDICATORS
FOR
NORMAL
OPERATION
.
C
HECK
FLUID
LEVEL
.
D
RAIN
WATER
FROM
AIR
/
FLUID
RESERVOIR
.
O
BSERVE
FOR
FLUID
LEAKS
.
O
BSERVE
FOR
UNUSUAL
NOISE
OR
VIBRATION
.
M
ONTHLY
:
C
LEAN
FLUID
COOLER
FINS
(
AIR
-
COOLED
).
W
IPE
DOWN
ENTIRE
UNIT
TO
MAINTAIN
APPEARANCE
.
E
VERY
6
MONTHS
OR
1000
RUNNING
HOURS
:
T
AKE
FLUID
SAMPLE
.
I
NSPECT
CONTROL
LINE
FILTER
(
S
)
AND
REPAIR
AS
NEEDED
.
M
AKE
SURE
FASTENERS
ARE
TIGHT
.
P
ERIODICALLY
/
YEARLY
:
R
EPLACE
AIR
/
FLUID
SEPARATOR
. (4000
HOURS
MAX
.)
L
UBRICATE
INLET
VALVE
(
MAY
BE
REQUIRED
MORE
OFTEN
IN
HUMID
ENVIRONMENTS
,
EVERY
4000
HOURS
).
C
HECK
ALL
BOLTS
FOR
TIGHTNESS
.
L
UBRICATE
MOTORS
.
R
EPLACE
FLUID
FILTER
. (2000
HOURS
)
R
EPLACE
AIR
FILTER
. (2000
HOURS
)
C
HECK
SAFETY
(HAT)
SHUTDOWN
SYSTEM
.
T
EST
PRESSURE
RELIEF
VALVE
FOR
PROPER
OPERATION
.
C
ONTACT
A
QUALIFIED
SERVICEMAN
.
I
NSTALL
INLET
VALVE
SERVICE
KIT
. (8000
HOURS
MAX
.)
E
VERY
8000
RUNNING
HOURS
(
OR
AS
INDICATED
BY
FLUID
ANALYSIS
):
R
EPLACE
FLUID
.
CAUTION!
Unusual noise or vibration indicates a problem. Shutdown the compressor and do
not restart until the source has been identified and corrected.
NOTICE!
Reference pages 28 thru 33 for more specific instructions on performing general
maintenance. Reference Section VII - Compressor Fluids for instructions regarding
taking fluid samples and selecting an appropriate fluid for your machine.
NOTICE!
Failure to follow these maintenance and service recommendations may adversely
affect your warranty. Maintain accurate and complete maintenance records to ensure
warranty compliance.
35
Содержание QSI-90
Страница 2: ......
Страница 70: ...Appendix A Dimensional Drawings QSI 90 120 140 micro 66...
Страница 71: ...Appendix A Dimensional Drawings QSI 90 120 140 micro dry 67...
Страница 72: ...Appendix A Dimensional Drawings QSI 90 120 140 micro tank mounted 68...
Страница 73: ...Appendix A Dimensional Drawings QSI 90 120 140 micro dry tank mounted 69...
Страница 74: ...Appendix A Dimensional Drawings QSI 90 120 140 guage 70...
Страница 75: ...Appendix A Dimensional Drawings QSI 90 120 140 guage dry 71...
Страница 76: ...Appendix A Dimensional Drawings QSI 90 120 140 guage tank mounted 72...
Страница 77: ...Appendix A Dimensional Drawings QSI 90 120 140 guage dry tank mounted 73...
Страница 78: ...Appendix A Dimensional Drawings QGV 20 25 30 460V 74...
Страница 79: ...Appendix A Dimensional Drawings QGV 20 25 30 460V dry 75...
Страница 80: ...Appendix A Dimensional Drawings QGV 20 25 30 460V tank mounted 76...
Страница 81: ...Appendix A Dimensional Drawings QGV 20 25 30 460V dry tank mounted 77...
Страница 91: ......