Section VI - Compressor Fluids
Fluid Filter
The fl uid fi lter is a spin on, full fl ow unit.
Replacement of the fi lter requires spinning
off the cartridge and replacing it with a
new one.
NOTICE!
Use genuine Quincy replacement
filters only.
The initial fi lter change should occur
after the fi rst 500 hours of operation.
During normal service, the fi lter cartridge
should be replaced under the following
conditions,
whichever occurs fi rst
:
as indicated by the fluid filter
♦
maintenance indicator when the fluid is
at normal operating temperature
every 2,000 hours
♦
every fluid change
♦
NOTICE!
The fluid filter maintenance indicator
may read high upon start up on
cool mornings due to sluggish fluid
creating higher than normal differential
pressures. Monitor indicator after the
fluid warms up.
Factors Affecting Fluid Life
To protect your investment, check for the
following, which can affect the long life of
QuinSyn:
1) High operating temperatures
2) Contaminants:
a. Other fl uids
b. Strong Oxidizers such as:
• aci
ds
• sul
fur
• chl
orine
• burnt fuel -
i.e. exhaust from: forklifts, boilers,
jet aircraft
• ni
trogen o
xides
• o
zone
• w
elding f
umes
• plastic molding fumes
c. A
mmonia
d. Solvent fumes:
• chl
orinated degr
easers
• i
nk so
lvents
e. Airborne dust and particles
f. Paper digester fumes
Locate your compressor in the coolest
area possible. For every 18°F above
195°F, the operating life of any fl uid is
reduced to about half that at 195°F. Some
mineral oils begin to form varnish at
temperatures above 200°F. QuinSyn fl uids
are more forgiving than mineral oil at high
temperatures. QuinSyn XP is designed to
operate at sustained temperatures above
200°F. The life of other QuinSyn fl uids will
be shortened at high temperatures.
Air intake should provide contaminant-
free, cool air. A Quincy heavy-duty intake
fi lter will reduce the risk of abrasion and
increased wear. An air fi lter does not
eliminate reactive gases. Inspect your fi lter
monthly and replace as required.
46
Содержание QSI-90
Страница 2: ......
Страница 70: ...Appendix A Dimensional Drawings QSI 90 120 140 micro 66...
Страница 71: ...Appendix A Dimensional Drawings QSI 90 120 140 micro dry 67...
Страница 72: ...Appendix A Dimensional Drawings QSI 90 120 140 micro tank mounted 68...
Страница 73: ...Appendix A Dimensional Drawings QSI 90 120 140 micro dry tank mounted 69...
Страница 74: ...Appendix A Dimensional Drawings QSI 90 120 140 guage 70...
Страница 75: ...Appendix A Dimensional Drawings QSI 90 120 140 guage dry 71...
Страница 76: ...Appendix A Dimensional Drawings QSI 90 120 140 guage tank mounted 72...
Страница 77: ...Appendix A Dimensional Drawings QSI 90 120 140 guage dry tank mounted 73...
Страница 78: ...Appendix A Dimensional Drawings QGV 20 25 30 460V 74...
Страница 79: ...Appendix A Dimensional Drawings QGV 20 25 30 460V dry 75...
Страница 80: ...Appendix A Dimensional Drawings QGV 20 25 30 460V tank mounted 76...
Страница 81: ...Appendix A Dimensional Drawings QGV 20 25 30 460V dry tank mounted 77...
Страница 91: ......