background image

S

tandard

 t

ermS

 

and

 C

onditionS

Q

uinCy

 C

ompreSSor

 

and

 o

rtman

 F

luid

 p

ower

 d

iviSionS

LEGAL EFFECT: Except as expressly otherwise agreed to in writing by an authorized representative of  

Seller, the following terms and conditions shall apply to and form a part of this order and any additional 

and/or different terms of Buyer’s purchase order or other form of acceptance are rejected in advance and 

shall not become a part of this order.
The rights of Buyer hereunder shall be neither assignable nor transferable except with the written consent 

of Seller.  
This order may not be canceled or altered except with the written consent of Seller and upon terms which 

will indemnify Seller against all loss occasioned thereby.  All additional costs incurred by Seller due to 

changes in design or specifications, modification of this order or revision of product must be paid for by 

Buyer.
In addition to the rights and remedies conferred upon Seller by this order, Seller shall have all rights and 

remedies conferred at law and in equity and shall not be required to proceed with the performance of this 

order if Buyer is in default in the performance of such order or of any other contract or order with seller. 
TERMS OF PAYMENT: Unless otherwise specified in the order acknowledgment, the terms of payment shall 

be net cash within thirty (30) days after shipment.  These terms shall apply to partial as well as complete 

shipments.  If any proceeding be initiated by or against Buyer under any bankruptcy or insolvency law, or 

in the judgment of Seller the financial condition of Buyer, at the time the equipment is ready for shipment, 

does not justify the terms of payment specified, Seller reserves the right to require full payment in cash 

prior to making shipment.  If such payment is not received within fifteen (15) days after notification of 

readiness for shipment, Seller may cancel the order as to any unshipped item and require payment of its 

reasonable cancellation charges.
If Buyer delays shipment, payments based on date of shipment shall become due as of the date when 

ready for shipment.  If Buyer delays completion of manufacture, Seller may elect to require payment 

according to percentage of completion.  Equipment held for Buyer shall be at Buyer’s risk and storage 

charges may be applied at the discretion of Seller.   
Accounts past due shall bare interest at the highest rate lawful to contract for but if there is no limit set 

by law, such interest shall be eighteen percent (18%).  Buyer shall pay all cost and expenses, including 

reasonable attorney’s fees, incurred in collecting the same, and no claim, except claims within Seller’s 

warranty of material or workmanship, as stated below, will be recognized unless delivered in writing to 

Seller within thirty (30) days after date of shipment.
TAXES: All prices exclude present and future sales, use, occupation, license, excise, and other taxes 

in respect of manufacture, sales or delivery, all of which shall be paid by Buyer unless included in the 

purchase price at the proper rate or a proper exemption certificate is furnished.
ACCEPTANCE: All offers to purchase, quotations and contracts of sales are subject to final acceptance by 

an authorized representative at Seller’s plant.
DELIVERY: Except as otherwise specified in this quotation, delivery will be F. O. B. point of shipment.  In 

the absence of exact shipping instruction, Seller will use its discretion regarding best means of insured 

shipment.  No liability will be accepted by Seller for so doing.  All transportation charges are at Buyer’s 

expense.  Time of delivery is an estimate only and is based upon the receipt of all information and 

necessary approvals.  The shipping schedule shall not be construed to limit seller in making commitments 

for materials or in fabricating articles under this order in accordance with Seller’s normal and reasonable 

production schedules.
Seller shall in no event be liable for delays caused by fires, acts of God, strikes, labor difficulties, acts of 

governmental or military authorities, delays in transportation or procuring materials, or causes of any kind 

beyond Seller’s control.  No provision for liquidated damages for any cause shall apply under this order.  

Buyer shall accept delivery within thirty (30) days after receipt of notification of readiness for shipment.  

Claims for shortages will be deemed to have been waived if not made in writing within ten (10) days after 

the receipt of the material in respect of which any such shortage is claimed.  Seller is not responsible for 

loss or damage in transit after having received “In Good Order” receipt from the carrier.  All claims for loss 

or damage in transit should be made to the carrier.

 

Quincy Compressor-QMOD

Содержание QMOD00008

Страница 1: ...uctions Parts List This manual contains important safety information and should be made available to all personnel who operate and or maintain this product Carefully read this manual before attempting...

Страница 2: ......

Страница 3: ...ent Connection 12 Alarm Connection 13 Section IV Operating Procedures Start up Procedure 14 Starting the Interface Program 15 Programming the Dryer 16 Interface Screen 16 Energy Management Application...

Страница 4: ......

Страница 5: ...s symbol identifies high pressure conditions which could result in personal injury or property damage Safety Precautions Notice Quincy explicitly excludes all responsibility and liability for damage a...

Страница 6: ...nection plus isolation from the compressed air supply and full depressurization Only trained and competent persons familiar with the electrical requirements of the unit as laid out in this manual and...

Страница 7: ...operation or maintenance of the dryer Operation of a known damaged dryer Failure to observe the information given in this manual concerning all life phases of the dryer Undertaking constructional or...

Страница 8: ...or manual please have the following information available Serial number _________________________ Date of commissioning _________________ The serial number can be found on the identification plate lo...

Страница 9: ...ately between drying and regenerating Component Description Main Components Reference the illustration on page 6 Item 2 Control Unit The top and bottom valve blocks are operated by solenoids within th...

Страница 10: ...ing screw 8 Pressure housing 9 Pressure housing retaining bolt 10 Desiccant cartridge w dust filter 11 Multiport manifold 12 Top cover 13 Top cover fixing screw 14 Rear panel 15 DIN connector 16 Banjo...

Страница 11: ...pe or the dryer is remote from the receiver a dewpoint dependent switch can be used to activate the energy management feature The energy management feature is supplied activated on all controllers Whe...

Страница 12: ...both Fasten filter bolts evenly to 4 Nm 2 94 Ft Lbs Fit 4 mm 5 32 black tubing to filter and drain valve inlet Pipe away condensate with 4 mm 5 32 tubing from drain outlet Ensure condensate is draine...

Страница 13: ...n If installation in a horizontal orientation is desired the inlet filter must be installed vertically and coupled as closely as possible to the inlet port on the manifold using a suitable pipe nipple...

Страница 14: ...yer inlets outlets front of dryer Electrical Supply Connection The dryer is designed to operate on either an AC or DC supply voltage Notice Ensure only one power source is connected at any one time th...

Страница 15: ...e not to lose it and connect the RS232 connector with the latch to the front of the dryer Energy Management and PC Interface Interfacing the controller with a PC The dryer controller has the ability t...

Страница 16: ...move DIN plug from EM connection on controller Remove blanking plug from cable entry nut on DIN plug Remove fixing screw and gasket from DIN plug body Separate DIN plug body internal from cover Remove...

Страница 17: ...n externally powered alarm device to terminals 1 and 2 of the alarm DIN connector With power removed from the dryer and the alarm lead wired as described in step 1 remove the cover from the DIN connec...

Страница 18: ...ness to function Observe display panel for one complete cycle Note cycle described is factory setting X Z Y POWER Power LED illuminates green and tower LED X illuminates green After 120 seconds tower...

Страница 19: ...the screen to establish the link between the PC and the dryer controller The serial number on the software must match the serial number on the controller to allow communications to be established If...

Страница 20: ...tings Allows previously stored settings to be loaded into the controller Stage Times Tower 1 Tower 2 Indicates the time that a tower is depressurized Repressurization Indicates the repressurization ti...

Страница 21: ...sor Dewpoint dependant energy management switching Dryer directly connected to local compressor and receiver Compressor load energy management switching Dry receiver application 15 second default EM d...

Страница 22: ...gs to be entered follow the rest of the instructions in this section The energy management feature can be deactivated by unchecking the Energy Management Active box Alternatively the DIN plug with jum...

Страница 23: ...ect the Wet Receiver System box With this system active the high and low pressure set points of the compressor the internal volume of the receiver and the flow rate of the dryer must be input to calcu...

Страница 24: ...Section V Servicing Service and Fault Diagnosis REPRESSURIZATION CYCLE REPRESSURIZATION INCLUDING SECOND DRAIN 20 Quincy Compressor QMOD...

Страница 25: ...s or 12 000 hours Kit A 4 years or 24 000 hours Kit B 6 years or 36 000 hours Kit A 8 years or 48 000 hours Kit B 10 years or 60 000 hours Service overhaul recommended Please contact Quincy Compressor...

Страница 26: ...ted Remove retaining screw to remove front fascia panel Remove front fascia panel by tilting outwards and downwards Dryer with front fascia panel removed Refit front fascia panel by inserting tongue i...

Страница 27: ...plements or tools Thoroughly dry the purge plug and ensure that the o rings are in place and in good condition Push the purge plug into the port in the valve block Replace and tighten purge plug fixin...

Страница 28: ...the bonnets by removing four fixing screws The silencer can be removed for maintenance if necessary Separate the bonnets from the valve block Disconnect tubing from fitting on bonnet Locate and remove...

Страница 29: ...d the power indicator D will flash green When the reset has been successful indicator B will flash red once to confirm that it has been completed successfully Changing the Desiccant Cartridges Follow...

Страница 30: ...time of ordering and used for product selection The table below gives possible causes and corrective actions to faults that may occur on the dryer Problem Possible cause Action Poor dewpoint Liquid w...

Страница 31: ...it Flashing red P1 X LED Replace solenoid valve Right solenoid open or short circuit Flashing red P1 Y LED Replace solenoid valve Controller fault Flashing red P2 Power LED Replace controller Lower po...

Страница 32: ...ryer Sizing Table Dryer Model Pipe Size in Inlet Flow Rate Dryer Configuration Dimensions mm Dimensions in Nm3 h SCFM L min A B C A B C QMOD00008 3 8 14 8 227 Simplex 565 281 92 21 7 11 06 3 6 QMOD000...

Страница 33: ...77 30 86 35 95 40 104 45 113 50 122 Temperature Correction Factor TCF 1 07 1 06 1 04 1 00 0 93 0 78 0 64 Dewpoint C F 40 40 70 100 Dewpoint Correction Factor DCF 1 0 7 Specifications Standard Pressure...

Страница 34: ...Appendix A Technical Data Schematic Wiring and Fault Diagrams General Wiring Diagram Remote alarm wiring diagram 30 Quincy Compressor QMOD...

Страница 35: ..._________________________________________________________________ ____________________________________________________________________ _________________________________________________________________...

Страница 36: ...roller Assembly QMOD00008 thru QMOD00035 QMCD Energy Management and Software Interface CD QMOD00008 thru QMOD00035 QMCP00030 Prefilter includes connecting kit and drain pipe assembly for solenoid drai...

Страница 37: ...llen key 1 6mm Sealing o rings and washers Instruction leaflet 12 000 Hour Service Kits Model Part Number QMOD00008 QMDC008 12000 QMOD00010 QMDC010 12000 QMOD00015 QMDC015 12000 QMOD00025 QMDC025 1200...

Страница 38: ...risk and storage charges may be applied at the discretion of Seller Accounts past due shall bare interest at the highest rate lawful to contract for but if there is no limit set by law such interest...

Страница 39: ...ned to seller freight prepaid for inspection Seller warrants repaired or replaced parts of its own manufacture against defects in materials and workmanship under normal use and service for ninety 90 d...

Страница 40: ..._______________________________________________________ ____________________________________________________________________ ____________________________________________________________________ ______...

Страница 41: ......

Страница 42: ...2007 Quincy Compressor All Rights Reserved Litho in U S A Quincy Compressor Products 217 222 7700 E mail info quincycompressor com Website www quincycompressor com...

Отзывы: