• The
controller
stops and starts the cooling fans
When at partial or no load the dew-point pressure stays below the set-point, the
controller
opens solenoid
valve
(210) and hot, high-pressure gas is fed through hot-gas by-pass valve (208) to the evaporator circuit to
prevent
the evaporator temperature from dropping below 0 ˚C (32 ˚F).
2.5
Condensate drain system
Description
Electronic water drain location on QED 650-1050
Electronic water drain functioning
1
Inlet
2
Supply line
3
Pilot valve
4
Diaphragm
5
Sensor
Instruction book
22
2920 1818 00
Содержание QED 650