6. Remove the drain valve by unscrewing the retaining nut underneath the bowl.
7. Remove the O-ring from the filter head and clean the o-ring groove. Position a new O-ring in
the filter head.
8. Reinstall the drain valve in the bowl using the retaining nut (tightening torque 3 Nm).
9. Reposition the new filter element within the filter head.
10. Screw the bowl completely on the head.
A small amount of acid-free vaseline may be applied to screw threads and O-rings to
facilitate the assembly.
4.3
Service intervals
P, G, C, S, D filters
The filter elements of oil mist filters (P, G, C) should be replaced after 8000 hours. The gauge or
pop-up is not a measure, as a typical oil mist filter operates in the steady state mode during its
life and this mode is e.g. 125 mbar.
Instruction book
20
2920 7195 00