35
TE ST
RESE T
I NVIO
I P
TE ST
RESE T
I NVIO
LP
TE ST
RESE T
I NVIO
TE ST
RESE T
I NVIO
TEST
RESET
INVIO
EE
N Pr.
RANGE
UNITS
DESCRIPTION
1
2 – 18
Amp.
Motor power consumption on opening
2
2 – 18
Amp.
Motor power consumption on closing
3
1 – 5
cm/sec2
Acceleration when opening
4
1 – 5
cm/sec2
Acceleration when closing
5
10 – 60
cm/sec
Speed when opening
6
10 – 60
cm/sec
Speed when closing
7
3 – 15
cm/sec
Approach speed when opening
8
3 – 15
cm/sec
Approach speed when closing
9
3 – 35
cm
pproach distance when opening
10
3 – 25
cm
Approach distance when closing
11
5 – 90
%
Partial opening percentage
12
0 – 5
cm
Manual travel
13
0 – 30
sec.
Delay for automatic closing
14
0 – 30
sec.
Delay for auxiliary closing
15
0 – 30
sec.
Delay for partial closing
16
1 – 10
decimi/sec
Time for electric lock
17
0 – 15
number
System configuration menu 1
18
0 – 15
number
System configuration menu 2
19
0 – 1
number
System configuration menu 3
20
0 – 9
number
1st digit PIN code (A)
21
0 – 9
number
2nd digit PIN code (B)
22
0 – 9
number
3rd digit PIN code (C)
23
0 – 9
number
4th digit PIN code (D)
NOTE: during the programation remember that the speed and weight of the
leaves are proportional to the current drawn by the motor, then in case of
changes in the speed you need to adjust current supply (range 1-2)
Otherwise you the control panel will report an obstacle error due to the over
absorption for the output current
Figure 1. List of programming parameters