OWNER’S GUIDE

ROOF MOUNT MODELS

DO NOT THROW AWAY! SERIAL NUMBER FOR FAN IS LOCATED ON 
BACK COVER OF OWNER’S GUIDE. RETAIN IN A SAFE PLACE.

Содержание AFR SMT-2.0

Страница 1: ...IETCOOL DIFFERENCE ADVANCED WHOLE HOUSE FANS THE NATURAL CHOICE FOR ENERGY SAVINGS OWNER S GUIDE ROOF MOUNT MODELS DO NOT THROW AWAY SERIAL NUMBER FOR FAN IS LOCATED ON BACK COVER OF OWNER S GUIDE RET...

Страница 2: ...Only qualified service personnel should service the QuietCool system The user should not attempt to service the product 7 Building Codes Always follow Local Building Codes when installing appliances...

Страница 3: ...en warehouse buildings The QuietCool Roof Mount Fans offer great versatility for any system you are looking to put in QuietCool Roof Mount Fans can be used as an attic fan as a whole house fan with a...

Страница 4: ...y or effectively as it could with 1 750 attic venting But don t worry the system will still operate if there is not enough venting Insufficient venting is a very simple problem to fix Roofing contract...

Страница 5: ...ing Started Always follow Local Building Codes because the fan may require specific fasteners or anchoring systems not discussed in this installation guide Installation should be done by a licensed ro...

Страница 6: ...g in a sweeping motion under the shingles cutting through any roofing nails or staples Continue cutting counterclockwise around the vent hole until reaching the 9 o clock position Using a roofing knif...

Страница 7: ...the center of the vent hole Partially insert a screw into the center point mark NOTE If you have a tile roof you will need to move the tiles out of the way before tracing and cutting See Figure 2 24...

Страница 8: ...wall studs and mark the location for the box to be installed Figure 2 3B Using a drywall saw cut out the drywall Figure 2 3C Place the ceiling box if applicable over the ceiling cut out Figure 2 3D A...

Страница 9: ...Roof With Duct Works with CRB and FLT Models Sloped Roof With Duct Works with SLP Models EXTREMELY IMPORTANT It is very important that you install the RM fans correctly as shown in the following diag...

Страница 10: ...ction box 3 With a wire nut tie the white common wire together Then tie the black wires together 4 Ground the green wire from the fan and the ground wire from the Romex to the junction box NOTE When t...

Страница 11: ...the fan s junction box tie the black wire from the fan to the taped white wire 7 Tie the two remaining black wires together Then tie the remaining copper wires together Figure 3 2A Ground the fan to...

Страница 12: ...screw ground the green wire from the fan to the handy box 5 With a wire nut tie the black wire from the fan to the red wire from the timer 6 Then tie the black wire from the power source to the black...

Страница 13: ...2030 2116 Watts 15 26 35 47 62 81 104 129 159 170 All specs are approximate For the most up to date specs please visit QuietCoolSystems com The QuietCool Smart Attic Fan will help your attic stay cool...

Страница 14: ...trouble installing or operating your new QuietCool Specialty Series Fan please visit our website at www QuietCoolSystems com or call us at 951 325 6340 for support QuietCool is Proudly Designed and B...

Страница 15: ...riginal date of purchase C This warranty does not cover any of the following 1 Incidental or consequential damage resulting from the operation of our equipment or any malfunction thereof 2 Cost of ser...