5:6
2005-09
Trouble shooting
fe
lsö
kn
in
g
cd
c.
in
d
d
Trouble shooting Electrodrive CDC
For installation and operation, see Operator’s Manual 12155016.
Symptom A
ON/OFF lamp does not give light when P0 is activated
1. Press P4 and / or P5
a. If L1 and/or L2 gives light, exchange lamp in P0
b. If L1 and/or L2
doesn’t
give light, check power source including fuses. See Wiring
diagram in Operator’s manual 12155016.
2. Check L10 and L11
a. If L10 and L11
doesn’t
give light, connect connector C1 directly to C2. If then L10 and
L11 gives light, exchange CANBUS cable.
b. Disconnect seven-pole connector for loader
c. If L10 and L11
doesn’t
give light, exchange control box. If that doesn’t help, see d.
d. If L10 and L11
doesn’t
give light, exchange joystick.
Symptom B
No function for boom and bucket
1. Factory setting
a. Restore factory setting. See Manual 12155016.
2.Check error codes on control box and joystick
a. Check the reason for error code in error code list. Code 3+4 deactivated by pressing P5. See
Manual 12155016.
b. Connect ground cable between bracket for Joystick and chassis. See manual 12155016.
3. Check signal transmission
a. When manoeuvring the joystick in X- and Y- direction, L12, L13, L14 and L15 shall give
light for each respective direction. L16 is always giving light 30sec after start and 4sec after
manoeuvring.
4. Check CANBUS-cable
a. Connect connector C1 to C2
5. Check connector C3
a. Cleanse
b. Check connector pins in connector
6. Check servo pressure
a. Increase to 2000 rpm
b. Measure servo pressure in M (BSP 1/4”). Use equipment withstanding 0-210bar.
c. Override proportional pressure reducing valve ”C” (only for open centre) according
to”Symptom B”, 7a.
d. Check spool for servo pressure generating (only open centre)
7. Check proportional pressure reducing valves
a. Override proportional pressure reducing valves. Solenoids are activated mechanically in
hole Ø 2mm close to the connector. See manual 12155016.
b. Proportional pressure reducing valves are interchangeable
8. Check system pressure
a. Measure pressure in port P
Содержание Q20
Страница 2: ......
Страница 4: ......
Страница 6: ...Preface 1 2 2005 09 product identification subframe indd Subframe identification...
Страница 7: ...Preface 2005 09 1 3 product identification subframe indd Subframe system DS DM DL...
Страница 8: ...Preface 1 4 2005 09 product identification subframe indd...
Страница 13: ...2005 05 2 5 Safety instructions 9020012107a indd Location of warning decals EU...
Страница 14: ...2 6 2007 01 Safety instructions 9020013107a indd Location of warning decals NA...
Страница 25: ...Installation 2005 09 4 7 joystick och kabel_safety switch indd Mounting instructions Safety Switch...
Страница 26: ...4 8 2005 05 Installation 9090012207a_tm indd Diagram...
Страница 27: ...Installation 2005 09 4 9 elschema_harness for loader indd Electrical circuit P N 5102048 5102049 and 5102050...
Страница 28: ...Installation 4 10 2005 09 hydscheman indd Hydraulic Circuits Open Center Walvoil P N 550017 and 10550054...
Страница 29: ...Installation 2005 09 4 11 hydscheman indd Open Center Walvoil P N 521622 B1 A1 T1 T P B2 A2 185 bar...
Страница 30: ...Installation 4 12 2005 09 hydscheman indd Open Center Nordhydraulic P N 10550062...
Страница 31: ...Installation 2005 09 4 13 hydscheman indd Load Sensing Walvoil P N 550035...
Страница 32: ...Installation 4 14 2005 09 hydscheman indd Load Sensing Walvoil P N 521622 B1 A1 T P B2 A2 Ls a1 b1 a2 b2 0 6 mm...
Страница 34: ...Installation 4 16 2005 09 hydscheman indd Without options...
Страница 44: ...5 10 2005 09 Trouble shooting fels kning inre l ckage indd...